Approach 1 / 2
1
- Altimeters setting (QNH) .............................................................. Set / Check
2
- Minimums ..................................................................................... Set / Check
3
- COM / NAV / GPS ........................................................................ Set / Check
4
- Pressurization ....................................................................................... Check
5
- LFE ....................................................................................................... Check
6
- Fuel gauges .......................................................................................... Check
Check for quantity and imbalance
7
- Fullest tank ........................................................................................... Select
8
- AMPS / VOLTS ..................................................................................... Check
CAUTION
If heavy precipitation, set IGNITION pushbutton and INERT SEP switch to ON.
9
- DE ICE SYSTEM mode switch .................................................... As required
Depending on external conditions, refer to procedure:
Flight under Heavy Precipitations in Subsection 4.5.
Flight into Known Icing Conditions in Subsection 4.5.
Flight into Severe Icing Conditions in Subsection 4.5.
Prior to descent in moist conditions and to avoid canopy misting:
10 - DEFOG pushbutton .......................................................................... ON
Status light in green
NOTE
The demisting function is automatically switched OFF 10 minutes after
the DEFOG pushbutton has been set to ON.
If misting continues:
11 - Perform procedure ............
Windshield Misting or Internal Icing in
12 - INERT SEP switch .................................................................................... ON
Continue ►
Pilot's Information Manual
Section 4
Normal Procedures
PIM TBM 960 - Edition 0
Rev. 01
Page 4.4.52
PIM - DO NOT USE FOR FLIGHT OPERATIONS