Engine Start 2 / 3
► Continuing
11 -
STARTER
..................................................................................... Check ON
12 -
MAIN GEN
.................................................................................... Check ON
When Ng > 8%:
13 -
IGNITION
...................................................................................... Check ON
NOTE
The FADEC system introduces fuel following ignitor excitation.
14 - ITT, Ng, OIL °C and OIL PSI .............................................................. Monitor
Aborting start procedure:
The FADEC automatically aborts starting procedure if:
-
light-up is not detected within 13 seconds after fuel has been injected
into combustion chamber,
-
Ng does not increase after light-up,
-
ITT exceeds 945 °C.
If ITT > 850 °C:
Manually abort the start sequence as follows:
15 - STARTER switch .............................................................. ABORT
2 seconds, then release
After an aborted start, the FADEC automatically commands a dry motoring
run for 30 seconds:
CAUTION
If the start sequence is aborted by setting the ENGINE MODE switch to
OFF, the FADEC will not command an automatic dry motoring. In this
case, perform a manual dry motoring after engine shutdown – refer to
procedure
16 -
ABORTING START
............................................................. Check ON
17 -
AUX BP ON
....................................................................... Check OFF
Continue ►
Pilot's Information Manual
Section 4
Normal Procedures
PIM TBM 960 - Edition 0
Rev. 01
Page 4.4.24
PIM - DO NOT USE FOR FLIGHT OPERATIONS