xStack DGS-3612G Layer 3 Gigabit Ethernet Managed Switch CLI Manual
config command_prompt
Purpose
Used to configure the command prompt for the Command Line
Interface.
Syntax
config command_prompt [<string 16> | username | default]
Description
This command is used to configure the command prompt for the CLI
interface of the Switch. The current command prompt consists of
“product name + : + user level + product name” (ex. DGS-3612G:4#).
The user may replace all parts of the command prompt, except the # by
entering a string of 16 alphanumerical characters with no spaces, or the
user may enter the current login username configured on the Switch.
Parameters
<string 16>
- Enter an alphanumeric string of no more than 16
characters to define the command prompt for the CLI interface.
username
– Entering this parameter will replace the current CLI
command prompt with the login username configured on the Switch.
default
– Entering this parameter will return the command prompt to its
original factory default setting.
Restrictions The
reset
command will not alter the configured command prompt, yet
the
reset system
command will return the command prompt to its
original factory default setting.
Only administrator-level users can issue this command.
Example usage:
To configure the command prompt:
DGS-3612G:4#config command prompt Trinity
Command: config command prompt Trinity
Success.
Trinity#
config greeting_message
Purpose
Used to configure the greeting message or banner for the opening
screen of the Command Line Interface.
Syntax
config greeting_message {default}
Description
This command is used to configure the greeting message or login
banner for the opening screen of the CLI.
Parameters
default
– Adding this parameter will return the greeting command to its
original factory default configuration.
Restrictions The
reset
command will not alter the configured greeting message, yet
the
reset system
command will return the greeting message to its
original factory default setting.
The maximum character capacity for the greeting banned is 6 lines and
80 characters per line. Entering Ctrl+W will save the current configured
banner to the DRAM only. To save it into the FLASH memory, the user
must enter the save command.
Only administrator-level users can issue this command.
Example usage:
To configure the greeting message: