Cynko
Met
RS-1500
51
Figure 18. Connection to spreader
1
–
Flow regulator
2
–
Feed/return hoses (interchangeable)
Table 7. Parameters of MP50 hydraulic motor (tilting plate adapter)
Item
no.
Parameter
Work mode
Value
1. Max. Torque [Nm]
continuous
94
intermittent
119
2. Max. Revolutions [rpm]
continuous
1210
intermittent
1515
3. Max. Pressure [bar]
continuous
140
intermittent
175
4. Max. Oil flowrate [L/min]
continuous
60
intermittent
70
5. Max. Performance [kW]
continuous
10.1
intermittent
12.2