CUB CRAFTERS, INC.
CC11-160 MAINTENANCE MANUAL
6.3.12
Manual number SSC10000AMM
Page: 4
Date: 10/28/2010
1.2. CARBURETOR
HEAT
Figure 6.3.12.2: Carburetor Heat Valve
(1) INSTALLATION OF CABLE TO VALVE ARM SWIVEL FITTING
(a) Insert the carburetor heat control cable end through the swivel fitting stud.
(b) Insert the threaded end of the stud through the swivel fitting and through the
carburetor heat valve arm.
(c) Place the AN960-10 washer and AN310-3 castle nut on the stud and tighten it
one half turn past finger tight.
(d) Test the travel of the carburetor heat control knob in the cockpit and adjust the
position of the cable within the fitting. When you are satisfied the position is
correct, tighten the castle nut and install an AN380-2-2 cotter pin.
Содержание CARBON CUB SS CC11-160
Страница 2: ...INTENTIONALLY LEFT BLANK...
Страница 23: ...CHAPTER 5 AIRCRAFT MAINTENANCE MANUAL...
Страница 24: ...INTENTIONALLY LEFT BLANK...
Страница 115: ...CHAPTER 6 LINE MAINTENANCE REPAIRS AND ALTERATIONS...
Страница 116: ...INTENTIONALLY LEFT BLANK...
Страница 325: ...CHAPTER 7 HEAVY MAINTENANCE REPAIRS AND ALTERATIONS...
Страница 326: ...INTENTIONALLY LEFT BLANK...
Страница 331: ...CHAPTER 8 OVERHAUL...
Страница 332: ...INTENTIONALLY LEFT BLANK...
Страница 338: ...CUB CRAFTERS INC CC11 160 MAINTENANCE MANUAL 8 Manual number SSC10000AMM Page 4 Date 04 24 2009 INTENTIONALLY LEFT BLANK...
Страница 339: ...CHAPTER 9 MAJOR REPAIRS AND ALTERATIONS...
Страница 340: ...INTENTIONALLY LEFT BLANK...
Страница 345: ...CHAPTER 10 TASK SPECIFIC TRAINING...
Страница 346: ...INTENTIONALLY LEFT BLANK...
Страница 351: ...CHAPTER 11 SAFETY DIRECTIVES COMPLIANCE...
Страница 352: ...INTENTIONALLY LEFT BLANK...