Chapter 4. Web Configuration & Operation
329
CHAPTER 4
WEB OPERATION & CONFIGURATION
Clock Time Properties Data Set:
The clock time properties data set is defined in the IEEE 1588 Standard. The data set
is both configurable and dynamic, i.e. the parameters can be configured for a grandmaster. In a slave clock the
parameters are overwritten by the grandmasters timing properties. The parameters are not used in the current PTP
implementation.
Servo Parameters:
Set up PTP clock servo data.
Display:
Offset from Master, MeanPathDelay, clockAdjustment are logged on the debug terminal when "True" is
selected. Do not display when "False" is selected.
P_Enable:
Select "True" to enable the P component in regulator. Select "False" to exclude P part o fthe algorithm.
I_Enable:
Select "True" to enable the I component in regulator. Select "False" to exclude I part o fthe algorithm.
D_Enable:
Select "True" to enable the D component in regulator. Select "False" to exclude D part o fthe algorithm.
"P" Constant:
P component in regulator. The allowed value is 1 to 1000.
"I" Constant:
I component in regulator. The allowed value is 1 to 1000.
"D" Constant:
D component in regulator. The allowed value is 1 to 1000.
Unicast Slave Configuration:
When operating in IPv4 Unicast mode, the slave is configured up to 5 master IP
addresses. The slave then requests Announce messages from all the configured masters. The slave uses the BMC
algorithm to select one as master clock, the slave then request Sync messages from the selected master.
Duration:
Configure the number of seconds a master is requested to send Announce/Sync messages. The request is
repeated from the slave each Duration/4 seconds.
ip_address:
Configure IPv4 Address of the Master clock.
grant:
The granted repetition period for the sync message.
CommState:
The state of the communication with the master, possible values are:
IDLE:
The entry is not in use.
INIT:
Announce is sent to the master (Waiting for a response).
CONN:
The master has responded.
SELL:
The assigned master is selected as current master.
SYNC:
The master is sending Sync messages.
Ports Configuration
Click on “Ports Configuration” button to configure timing values.
Содержание MSW-4424C Series
Страница 1: ...1 MSW 4424C MSW 4424CS L2 Gigabit Carrier Ethernet Switch ...
Страница 382: ......