Chapter 4. Web Configuration & Operation
236
CHAPTER 4
WEB OPERATION & CONFIGURATION
Action:
Permit or deny a frame based on whether it matches a rule defined in the assigned policy.
Rate Limiter ID:
Select a rate limiter ID to apply to a port. Rate Limiter rule can be set up in “Rate Limiters”
configuration page.
Port Redirect:
Select a port to which matching frames are redirected.
Logging:
Enable logging of matched frames to the system log. To view log entries, go to System menu and then click
the “System Log Information” option.
Shutdown:
This field is to decide whether to shut down a port when matched frames are seen or not.
State:
Select a port state.
Enabled:
To re-open a port.
Disabled:
To close a port.
Counters:
The number of frames that have matched the rules defined in the selected policy.
4.3.4.2.3.2 Rate Limiters
Rate Limiter ID:
Display every rate limiter ID.
Rate:
Specify the threshold above which packets are dropped. The allowed values are 0–3276700 pps or 1, 100, 200,
300…1000000 kbps.
Unit:
Select the unit of measure used in rate.
Содержание MSW-4424C Series
Страница 1: ...1 MSW 4424C MSW 4424CS L2 Gigabit Carrier Ethernet Switch ...
Страница 382: ......