Chapter 4. Web Configuration & Operation
304
CHAPTER 4
WEB OPERATION & CONFIGURATION
EIR:
The Excess Information Rate (EIR) for MEF type bandwidth profile. The allowed range is from 0 through 10000000
kilobit per second.
EBS:
The Excess Burst Size (EBS) for MEF type bandwidth profile. The allowed range is from 0 through 100000 bytes.
4.3.24.4 EVCs
Click on the plus sign
to add a new entry and configure its detailed settings.
NNI Ports:
Select the network interface for EVC.
EVC Parameters
EVC ID:
The EVC ID identifies the EVC. The allowed range is from 1 through 4096.
VID:
The VLAN ID in the PB network. It may be inserted in a C-tag, S-tag or S-custom tag depending on the NNI port
VLAN configuration. The allowed range is from 1 through 4095.
IVID:
The Internal/classified VLAN ID in the PB network. The allowed range is from 1 through 4095.
Learning:
The learning mode for the EVC controls whether source MAC addresses are learned for frames matching the
EVC. Learning may be disabled if the EVC only includes two UNI/NNI ports. The possible values are:
Enabled:
Learning is enabled (MAC addresses are learned).
Disabled:
Learning is disabled (MAC addresses are not learned).
Policer ID Filter
: The ingress bandwidth profile mode for the EVC. The possible values are:
Specific:
The allowed range is from 1 through 2048.
Discard:
All received frames are discarded for the EVC.