SBX-3 Reference Manual
48
Counterpoise Ground
MBA-3
* Vehicle Chasis
* Steel Hull
* Copper Grounding Plate
SBX-2 Eval Module
Figure 4-1 Receiver & MBA-3/MBA-3A Grounding Requirement
The MBA-3 has an 11-inch pigtail terminated with a BNC-S connector.
The MBA-3A possesses a 10-meter pigtail terminated with a removable
BNC-P connector.
The BNC-P connector of the MBA-3A is removable to aid in routing the
cable through a bulkhead with a minimal opening. Do not cut the
connector of the MBA-3A off in order to run the cable. Also, minimize
the number of times that connector is removed to maintain the integrity
of the connection. When removing the BNC termination from the MBA-
3A cable, be sure to note the configuration of the various parts within
the connector so that they can be re-installed in the same order.