Crown Broadcast FME 350W to 2000W User Manual– 05/2013
Page 68
Crown Broadcast, a division of International Radio & Electronics Corporation 25166 Leer Drive, Elkhart, Indiana, 46514-5425 USA
Ph +1 (574) 262 8900
For Telnet connections, the embedded website identifiers will be requested with the command prompts
LOGIN USER and LOGIN PASSWORD (see section 9.6.5).
6.2. Serial
commands
6.2.1. System
commands
NAME
Access
(R/W)
Possible value on the serial port
of the unit
Comments
LOGIN
R/W
XXXX,X=[0…z] "LOGGED" ou
"NOT LOGGED"
Logs the user and allows them to update
variables if the password is correct. Returns
Logged or not logged
LOGOUT
W
Logs out the user and locks all variables.
SYS.CID
R/W
[0..31]
Unit identifier used by the CAN bus.
SYS.CIDIP
R/W
[0..31]
Unit identifier used by the IP option CAN bus
SYS.CIDUC
R/W
[0..31]
Unit identifier used by the CAN2 bus.
SYS.COM1.ECHO R/W "ON"
or
"OFF"
Adds the local echo on the rear panel serial
port
SYS.COM1.SPEED
R/W
9600,19200,38400,57600,115200 Speed of the rear panel serial port 1
SYS.COM2.ECHO R/W "ON"
or
"OFF"
Adds the local echo on the rear panel serial
port
SYS.COM2.SPEED
R/W
9600,19200,38400,57600,115200 Speed of the rear panel serial port 2
SYS.DATE
R/W
DD/MM/YY
Reads and sets the amplifier date
SYS.DATECALIB
R
DDMMYYYY
Date of the last calibration
SYS.GPIO.CONF1 R/W
"AMB" or "FAN1" or "VOLT" or
"HEAT" or "FAN2" or "CURRENT"
or "PWR"
Sets the remote monitoring ANA3 on the
optional GPIO Analog board
SYS.GPIO.CONF2 R/W
"AMB" or "FAN1" or "VOLT" or
"HEAT" or "FAN2" or "CURRENT"
or "PWR"
Sets the remote monitoring ANA4 on the
optional GPIO Analog board
SYS.GPIO.IN.ACT
R
XX X=[A..F;0..9]
Indicates the corresponding RC when
managed manually (see
SYS.GPIO.IN.MASK)
SYS.GPIO.IN.MASK
R/W
XX X=[A..F;0..9]
Sets the RC control either by the control
board or manually. Hexadecimal code: each
bit corresponds to an input. Ex: A1
(10100001) indicates the RC 1, 6 and 8 are
managed manually
SYS.GPIO.OUT.ACT
R/W
XX X=[A..F;0..9]
Enables the corresponding RM when
managed manually (see
SYS.GPIO.OUT.MASK)
SYS.GPIO.OUT.MASK
R/W
XX X=[A..F;0..9]
Sets the RM control either by the control
board or manually. Hexadecimal code: each
bit corresponds to an input: Ex: 21
(00100001) indicates RM 1 and 6 are
managed manually.
SYS.HARDREL
R
xx.xx.xx x=[0..9]
Hardware version: example "3.0.1"
SYS.IP.ADR
R/W
XXX.XXX.XXX.XXX X=[0…9]
IP address of the optional IP board
SYS.IP.GW
R/W
XXX.XXX.XXX.XXX X=[0…9]
Network gateway of the optional IP board
SYS.IP.MAC
R/W
XX:XX:XX:XX:XX:XX:XX:XX
X=[A..F;0..9]
Mac address of the optional IP board
SYS.IP.MASK
R/W
XXX.XXX.XXX.XXX X=[0…9]
IP mask of the optional IP board
SYS.KEY.ADD R/W
ADD
Generates a key to enable the specified
option
SYS.KEY.REM R/W
REM
Generates a key to disable the specified
option