Crown Broadcast FME 350W to 2000W User Manual– 05/2013
Page 117
Crown Broadcast, a division of International Radio & Electronics Corporation 25166 Leer Drive, Elkhart, Indiana, 46514-5425 USA
Ph +1 (574) 262 8900
Manual acknowledgement
for Traps V1 and Traps V2c. A specific OID
(“alarmPendingAlarmsalarmAck”) is extracted and its variables are sent with the trap. The
manager must then execute a SET command. This method is more complex but is the only one
that can work with the version 1 of the protocol.
The acknowledgment mode (Trap V1, Trap V2c or Inform) is identical for all alarms. See the next section
“Notifications”
for additional settings.
With “SNMPv2c traps” notifications, it not possible to acknowledge traps.
In the same way, traps which do not require acknowledgment cannot be sent with the “Inform
SNMPv2c” format, even when this format is selected. This is the case with the ‘test’ trap as well as with
equipment information traps such as the ‘Equipment On’ trap.
9.6.7. Notifications
SNMP Actions
The user may replay traps that have not been acknowledged yet.
The user may also delete pending traps that have not been acknowledged yet.