![Crown FME 1000W Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/crown/fme-1000w/fme-1000w_user-manual_2690532019.webp)
Crown Broadcast FME 350W to 2000W User Manual– 05/2013
Page 19
Crown Broadcast, a division of International Radio & Electronics Corporation 25166 Leer Drive, Elkhart, Indiana, 46514-5425 USA
Ph +1 (574) 262 8900
3.1. Interface
panel
Indicators
Green CPU LED: CPU activity
Red FAULT LED: major fault
Yellow WARNING LED: minor fault
Red RF (3 dB) LED: RF fault (3 dB)
Red VSWR LED: VSWR fault
Green INTERLOCK LED: safety interlock
Green RF LED: RF on
Orange LOCAL LED: local mode
Screens
Back lighted LCD: displays operating parameters and menus.
Buttons
RF, local, +, -- and OK
3.2. Environmental
Nominal operating temperature
5°C to 45°C
Maximum operating temperature
0°C to 50°C
Warehousing temperature
-20°C to +70°C
Warehousing time
< 10 years
Cooling Internal
ventilation
Crown Broadcast FME 350 W: ~20 I/s
Crown Broadcast FME 750 W: ~20 I/s
Crown Broadcast FME 1000 W: ~20 I/s
Crown Broadcast FME 1500 W: ~55 l/s
Crown Broadcast FME 2000 W: ~55 l/s
3.3. Physical
Crown Broadcast FME 350 W / 750 W / 1000 W
Overall dimension
19’’ (482.6 mm) X 3U (133.5 mm) X 470 mm
Rack size without front panel
440.4 X 126.2 X 432 mm (WxHxD)
Enclosure depth required
600 mm
Mounting
19’’enclosure, with 4 M6X12 screws
Weight
around 13 kg
Crown Broadcast FME 1500 W / 2000 W
Overall dimension
19’’ (482.6 mm) X 3U (133.5 mm) X 690 mm
Rack size without front panel
440.4 X 126.2 X 620 mm (WxHxD)
Enclosure depth required
700 mm
Mounting
19’’enclosure, with 4 M6X12 screws
Weight
around 18 kg