Page 33
DURESS DIGIT
This address (P230E) is used to program the duress digit.
The duress digit is a number from 1-9 (“0” means the
duress function is disabled) .To create a duress alarm the
duress digit must be entered before a valid user code (eg
If the code was “123” and the duress number was “4”,
then entering a code of “4123” “Enter” would create a duress alarm).
P230E Duress Digit -
Value 1-9 (Default = 0, Disabled)
SETTING REAL TIME CLOCK
The Real Time Clock is used to Time & Date stamp the events in the Event Buffer. Ensure this is set correctly at the
time of installation so that the events have the proper time and date associated with them. The clock is programmed
in 24 hour format (e.g. 00:00-23:59).
P401E Real Time Clock Hour/Minute -
Value 0-2359
P403E Real Time Clock Day of Week -
Value 1-7 (where 1 = Sunday, 2 = Monday, 3 = Tuesday, etc)
P405E Real Time Clock Date -
Value 1-31
P406E Real Time Clock Month -
Value 1-12
P407E Real Time Clock Year -
Value 0-99
(Daylight Saving settings: NOT available in
V8.64 panels and above)
The real time clock can have preset automatic adjustments
for the start & finish of daylight saving if applicable. If a value
of “0” is entered at addresses P408 & P411 then no daylight
saving adjustments will apply. Otherwise set up the
parameters for the country concerned and the adjustments
will become automatic every year.
P408E Daylight Saving Start Sunday -
Value 0-5 - Default =
1
(0=daylight saving start time disabled)
P409E Daylight Saving Start Month -
Value 1-12 - Default =
10
P410E Daylight Saving Start Hour -
Value 0-23 - Default = 2
P411E Daylight Saving End Sunday -
Value 0-5 - Default = 3 (0=daylight saving end time disabled)
P412E Daylight Saving End Month -
Value 1-12 - Default = 3
P413E Daylight Saving End Hour -
Value 0-23 - Default = 3
When setting up a panel for the first time using daylight saving, you must ascertain whether daylight saving is
currently ACTIVE. If it is you must enter in P414E then 1E to tell the panel that daylight saving is ON to sync the
panel to daylight saving mode. If this is not done then when daylight saving finishes the panel will not adjust the
clock.
P414E Daylight Saving is Active (If LED #1 is On, Daylight Saving is currently active)
RESTORE FACTORY DEFAULTS
This address (P620E) is used to return the panel back to factory default settings.
P620E Restore Factory Defaults
RESTORING SELECTED DEFAULTS
P621E Restore User Codes to Default only.
P622E Restore all Program Addresses from 20-199 to Default
Duress Digit
0
Set Time HH:MM
18:23
Reset All
Done