2.8  Environmental Use Information

A

.

Rack-Mounting 

- To mount this equipment in a rack, please refer to the installation instructions 

located in the user manual furnished by the manufacturer of your equipment rack.

B. Mechanical Loading

 - Mounting of equipment in a rack should be such that a hazardous condition 

does not exist due to uneven weight distribution.

C

.

Elevated Operating Ambient Temperature 

- If installed in a closed or multi-unit rack assembly, 

the operating ambient temperature of the rack may be greater than room ambient temperature.  
Therefore, consideration should be given to Tmra.

D. Reduced Air Flow

 - Installation of the equipment in a rack should be such that the amount of air flow 

required for safe operation of the equipment is not compromised.  Additional space between unit 
may be required.

E. Circuit Overloading 

- Consideration should be given to the connection of the equipment to the supply 

circuit and the effect that overloading of circuits could have on over current protection and supply wiring.  
Appropriate consideration of equipment name plate rating should be used, when addressing this concern.

F. Reliable Earthing

 - Reliable earthing of rack-mounted equipment should be maintained.  

Particular attention should be given to supply connections other than direct connection to the 
Branch (use of power strips).

G. Top Cover

 - There are no serviceable parts inside the product so, the Top Cover should not be removed.  

If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED 
prior to Top Cover screw replacement.  FAILURE TO DO this may cause INGRESS and/or EGRESS 
emission problems.

1582-14 Manual_A

 

 

  Page 11

    

    06/22/09

Содержание 1582-14

Страница 1: ...n are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from...

Страница 2: ...anship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subasse...

Страница 3: ...nd CH2 are in alarm 3 Minimum Auto switching Initial Channel Select ICS Mode Switch stays on channel last selected by Manual or Remote selection after return to Auto if both channel alarms are clear o...

Страница 4: ...arm SWITCH RESET Resets switch to CH1 if it is good and switch is in the latch mode Also Resets REMOTE by returning operation to Auto Indicators LEDs CH1 ON LINE Turns green when Channel 1 is selected...

Страница 5: ...N 1 2 4 6 7 9 Not connected J8 Monitors and Cont trols Controls Connec ctor J8 Monitors and Controls Connector Function Pin Description ALARM 1 IN 13 Ground or Open selectable by JP2 JP102 gives CH1 a...

Страница 6: ...RM CH2 LED Turns red when Channel 2 clock times out or on external alarm input REMOTE LED Turns amber when REMOTE control is active MANUAL SELECT Switch 3 position switch as follows LEFT manually sele...

Страница 7: ...el 2 and stays there until the reset button is pushed on the front panel or by an external closure to ground on the remote RESET pin on J8 and then it switches to channel 1 If channel 1 alarms are cle...

Страница 8: ...tion DIP switch Selects the Initial Channel Select mode when JP1 2 3 JP101 102 103 in Dot and JP4 JP104 in Non dot S3 S103 positions 1 2 3 4 to ON ICS is enabled In the ICS mode the initial channel ca...

Страница 9: ...djust these switches to the desired length in 0 1 second increments position 1 0 1 seconds position 2 0 2 seconds etc see Figure 2 3 JP4 JP9 1 2 3 4 O F F ROCKER DOWN S3 ROCKER SWITCH DETAIL SHOWN WIT...

Страница 10: ...ual or Remote selection after return to Auto if both channel alarms are clear or both channels are in alarm Auto switching occurs only if current channel alarms and the other channel is clear Non dot...

Страница 11: ...he equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effec...

Страница 12: ...CHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 1582 14 Manual_A Page 12 0...

Отзывы: