MODEL 1582-14 Data Switch

1.0  General

1.1  Equipment Description 

- The 1582-14 Data Switch has two independent switches (A and B) in a single 1 

3/4” chassis. Each switch provides Auto, Manual, or Remote relay switching between CH1 and CH2 RS422 
clock or data signals on pins 3 and 8 with pin 5 ground and the other pins not connected.  

Clock or data transitions are detected from pin 3 and a clock (or data) presence alarm is activated if 

transitions are lost for a set period of time.  The time period from a loss of transitions (on pin 3) to a presence 
alarm is set with BCD switches on the PCB.

Alarm conditions on CH1 and CH2 are detected if clock is lost for a preset 0.1 to 0.9 seconds on the CH1 and 
CH2 input or a contact closure (to ground or an open, selectable). Switching logic can be selected as follows:

1) CH1 Prime Mode

 - Switches from CH1 to the CH2 only if CH1 alarms and CH2 is good. Switches 

back to CH1 when it is no longer in alarm or when both CH1 and CH2 are in alarm.

2) Latch to CH2 Mode

 - Switches from CH1 to CH2 if CH1 alarms and CH2 is good. Latches to CH2. 

Push Reset or ground Remote Reset pin to return to CH1 if it has no alarm or both CH1 and CH2 are in 
alarm.

3)  Minimum  Auto  switching,  Initial  Channel  Select  (ICS)  Mode 

- Switch stays on channel last 

selected by Manual or Remote selection after return to Auto if both channel alarms are clear or both 
channels are in alarm. Auto switching occurs only if current channel alarms and the other channel is 
clear.

Factory set mode is generally 

(1) CH1 Prime Mode.

  

When power is first applied and there are no alarms, CH1 is selected. On power loss CH1 is the selected 

channel. The Manual Select switch and contact closures to Remote Select pins (when in Auto), select CH1 or 
CH2 independent of alarms. LEDs indicate alarm and switch conditions for CH1 and CH2, REMOTE or 
MANUAL operation, and power on.

Data connectors are DB9, female. Contact closure inputs and outputs are via barrier strip. Dual power supplies 
provide redundant power to the 1582-14. The chassis is a 1 3/4” rack mount.

SWITCH A

MODEL 1582

POWER

1      2

   AUTO   

 CROSS TECHNOLOGIES, INC.

ON-
LINE

MANUAL 
SELECT

REM

ON-
LINE

ALM

CH 1 

CH 2

ALM

MAN

RESET

SWITCH B

   AUTO   

ON-
LINE

MANUAL 
SELECT

REM

ON-
LINE

ALM

CH 1 

CH 2

ALM

MAN

RESET

FIGURE 1.1 Model 1582-14 Front Panel

SELECTED 

DATA OUT

DATA 1 IN

DATA 2 IN

AUTO

CH 1 

CH 2

CONTROL

LOGIC

ALARM 

DET CH1

ALARM 

DET CH2

MANUAL 

SELECT

1   2

REM

1   2
ALM

DATA

 ALM

REM

RESET

FIGURE 1.2 Model 1582-14 Data Switch Block Diagram (Each Switch)

1582-14 Manual_A

 

 

  Page 3

    

    06/22/09

Содержание 1582-14

Страница 1: ...n are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from...

Страница 2: ...anship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subasse...

Страница 3: ...nd CH2 are in alarm 3 Minimum Auto switching Initial Channel Select ICS Mode Switch stays on channel last selected by Manual or Remote selection after return to Auto if both channel alarms are clear o...

Страница 4: ...arm SWITCH RESET Resets switch to CH1 if it is good and switch is in the latch mode Also Resets REMOTE by returning operation to Auto Indicators LEDs CH1 ON LINE Turns green when Channel 1 is selected...

Страница 5: ...N 1 2 4 6 7 9 Not connected J8 Monitors and Cont trols Controls Connec ctor J8 Monitors and Controls Connector Function Pin Description ALARM 1 IN 13 Ground or Open selectable by JP2 JP102 gives CH1 a...

Страница 6: ...RM CH2 LED Turns red when Channel 2 clock times out or on external alarm input REMOTE LED Turns amber when REMOTE control is active MANUAL SELECT Switch 3 position switch as follows LEFT manually sele...

Страница 7: ...el 2 and stays there until the reset button is pushed on the front panel or by an external closure to ground on the remote RESET pin on J8 and then it switches to channel 1 If channel 1 alarms are cle...

Страница 8: ...tion DIP switch Selects the Initial Channel Select mode when JP1 2 3 JP101 102 103 in Dot and JP4 JP104 in Non dot S3 S103 positions 1 2 3 4 to ON ICS is enabled In the ICS mode the initial channel ca...

Страница 9: ...djust these switches to the desired length in 0 1 second increments position 1 0 1 seconds position 2 0 2 seconds etc see Figure 2 3 JP4 JP9 1 2 3 4 O F F ROCKER DOWN S3 ROCKER SWITCH DETAIL SHOWN WIT...

Страница 10: ...ual or Remote selection after return to Auto if both channel alarms are clear or both channels are in alarm Auto switching occurs only if current channel alarms and the other channel is clear Non dot...

Страница 11: ...he equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effec...

Страница 12: ...CHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 1582 14 Manual_A Page 12 0...

Отзывы: