background image

2.6

  

Switch Mode Setup

 - The following gives the switch mode settings of the on board controls that can be 

changed in the field: 

SWITCH A 

JP1, JP2, JP3, JP4; S3; 

SWITCH B

 - JP101, JP102, JP103, JP104, S103 

(Section 2.3, Figure 2.3). All shown with external 

alarm = ground

.

1) CH1 Prime Mode

 - Switches from CH1 to the CH2 only if CH1 alarms and CH2 is good. Switches 

back to CH1 when it is no longer in alarm or when both CH1 and CH2 are in alarm

Non-dot - SWITCH A

 - JP1, JP3, JP4; 

SWITCH B

 - JP101, JP103, JP104

Dot

 

- SWITCH A

 - JP2; 

SWITCH B

 - JP102

S3 (SWITCH A), S103 (SWITCH B)

 - ALL TO OFF.

2) Latch to CH2 Mode

 - Switches from CH1 to the CH2 if CH1 alarms and CH2 is good. Latches to 

CH2. Push Reset or ground Remote Reset pin to return to CH1 if it has no alarm or both CH1 and CH2 
are in alarm.

Non-dot - SWITCH A

 - JP1, JP4; 

SWITCH B

 - JP101, JP104

Dot

 

- SWITCH A

 - JP2, JP3; 

SWITCH B

 - JP102, JP103

S3 (SWITCH A), S103 (SWITCH B)

 - ALL TO OFF.

3)  Minimum  Auto  switching,  Initial  Channel  Select  (ICS)  Mode 

- Switch stays on channel last 

selected by Manual or Remote selection after return to Auto if both channel alarms are clear or both 
channels are in alarm. Auto switching occurs only if current channel alarms and the other channel is 
clear.

Non-dot - SWITCH A

 - JP4, 

SWITCH B

 - JP104

Dot

 

- SWITCH A

 - JP1, JP2, JP3; 

SWITCH B

 - JP101, JP102, JP103

S3 (SWITCH A), S103 (SWITCH B)

 - ALL TO ON.

Factory set mode is generally 

1) CH1 Prime Mode

 ,

2.7

  

Operation

a.  Set the on board controls as desired (Section 2.4, 2.6, Figure 2.3).
b.  Install the 1582-14 in the equipment rack.
c.  Connect data to the DB-9 DATA connectors (J6, J7, J3 (CH1); J106, J107, J103 (CH2)).
d.  Connect to signals on the MONITORS AND CONTROLS connector, J8, as desired (see Figure 2.0, 
Table 2.0).
e.  Connect power via two power cords.
f.  Manually switch between channels 1 and 2 and be sure switching occurs.
g.  Switch to Auto. Alarm channel 1 and note that automatic switching occurs. Remove alarm to channel 
1 and note that the output switches as desired. Push RESET if in LATCH mode. Repeat for Channel 2.

h.  Check that CH 1 and CH 2 are selected when in Auto and momentary ground is applied to J8 pins 1 

and 2. Momentarily ground remote Reset pin 4 on J8 to return to Auto operation. 

1582-14 Manual_A

 

 

  Page 10

    

    06/22/09

Содержание 1582-14

Страница 1: ...n are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from...

Страница 2: ...anship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subasse...

Страница 3: ...nd CH2 are in alarm 3 Minimum Auto switching Initial Channel Select ICS Mode Switch stays on channel last selected by Manual or Remote selection after return to Auto if both channel alarms are clear o...

Страница 4: ...arm SWITCH RESET Resets switch to CH1 if it is good and switch is in the latch mode Also Resets REMOTE by returning operation to Auto Indicators LEDs CH1 ON LINE Turns green when Channel 1 is selected...

Страница 5: ...N 1 2 4 6 7 9 Not connected J8 Monitors and Cont trols Controls Connec ctor J8 Monitors and Controls Connector Function Pin Description ALARM 1 IN 13 Ground or Open selectable by JP2 JP102 gives CH1 a...

Страница 6: ...RM CH2 LED Turns red when Channel 2 clock times out or on external alarm input REMOTE LED Turns amber when REMOTE control is active MANUAL SELECT Switch 3 position switch as follows LEFT manually sele...

Страница 7: ...el 2 and stays there until the reset button is pushed on the front panel or by an external closure to ground on the remote RESET pin on J8 and then it switches to channel 1 If channel 1 alarms are cle...

Страница 8: ...tion DIP switch Selects the Initial Channel Select mode when JP1 2 3 JP101 102 103 in Dot and JP4 JP104 in Non dot S3 S103 positions 1 2 3 4 to ON ICS is enabled In the ICS mode the initial channel ca...

Страница 9: ...djust these switches to the desired length in 0 1 second increments position 1 0 1 seconds position 2 0 2 seconds etc see Figure 2 3 JP4 JP9 1 2 3 4 O F F ROCKER DOWN S3 ROCKER SWITCH DETAIL SHOWN WIT...

Страница 10: ...ual or Remote selection after return to Auto if both channel alarms are clear or both channels are in alarm Auto switching occurs only if current channel alarms and the other channel is clear Non dot...

Страница 11: ...he equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effec...

Страница 12: ...CHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 1582 14 Manual_A Page 12 0...

Отзывы: