2.0
Installation
2.1
Mechanical
- The 1582-14 is rack mounted by attaching the front panel to a rack through the four holes at
the edges of the panel.
2.2
Rear Panel Inputs and Outputs -
Figure 2.0 shows the input and output connectors on the rear panel.
AC1
POWER IN 1
1.5 A FUSE
AC2
POWER IN 2
1.5 A FUSE
J6
SWITCH A
DATA 1
J3
SWITCH A
DATA 2
J7
SWITCH A
SWITCHED DATA
J106
SWITCH B
DATA 1
J103
SWITCH B
DATA 2
J107
SWITCH B
SWITCHED
DATA
J8
MONITORS
AND
CONTROLS
AC
1
AC
2
DATA B2
DATA A1
1
J8
J3
GN
D
DATA B1
DATA B
DATA A
J7
J6
J103
J107
J106
A
DATA A2
B
FIGURE 2.0 1582-14 Rear Panel I/O
s
5 4 3 2 1
9 8 7 6
FIGURE 2.1 DB9 Pin-Outs
TABLE 2.0 Rear Panel Input/Output Connectors Pinout
J3, J6, J7, J103, J106
6,
J10
6, J107 - Datta
J3, J6, J7, J103, J106, J107 - Data Connectors
Function
Pin #
Description
DATA
3 8
RS422 Levels
GROUND
5
Ground
NO CONNECTION
1 2 4 6 7 9 Not connected
J8 - Monitors and Conttrols
Con
trols Connecctor
J8 - Monitors and Controls Connector
Function
Pin #
Description
ALARM 1 IN
13
Ground or Open (selectable by JP2, JP102) gives CH1 alarm
ALARM 2 IN
14
Ground or Open (selectable by JP2, JP102) gives CH2 alarm
REMOTE 1 IN
1
When in AUTO, momentary ground on this pin selects CH1
REMOTE 2 IN
2
When in AUTO, momentary ground on this pin selects CH2
REMOTE RESET IN
4
When in LATCH mode, ground resets switch to CH1, resets REMOTE to AUTO
MANUAL INDICATION*
8
Open collector output (<5
) to GND when in MANUAL mode
SWITCH 1 MON**
11
Relay closure to J8 pin 6 (<5
) when selected data is CH1 data
SWITCH 2 MON**
12
Relay closure to J8 pin 6 (<5
) when selected data is CH2 data
SWITCH MON COMMON
6
Common pin for SWITCH 1, 2 MONITOR
DATA ALARM*
9
Open collector (<5
) to GND when clock on CH1 or CH2 is lost
GROUND
3 7
Ground
NO CONNECTION
5 10 15
Not connected
*Max voltage able to be connected to this is +20 VDC @ 30ma.
**Max voltage to be connected to this is +30 VDC @ 100 ma.
1582-14 Manual_A
Page 5