3.2. Loopbacks
3.2.1. Loopback to E1 Line
E1-XL-IP
E1-XL-IP
E1 / G.703
Data received from E1 port is turned back to E1 port without processing and is trans-
ferred to a remote device over packet network. Data received from the remote device
from packet network is lost.
3.2.2. Loopback to Remote Device
E1-XL-IP
E1-XL-IP
E1 / G.703
Data received from a remote device over packet network is processed by the device
and transferred back for transmission to E1 port. Data received from E1 port is lost.