3.2 Internal Sensor Gas Types
Internal Electrochemical
Sensors
Part Number
Range
Lifespan
Ammonia (NH
3
)
LPT-M-NH3
0 - 500 ppm
~2 years
Carbon Monoxide (CO)
LPT-M-TCO
0 - 200 ppm
~6 years
Chlorine (Cl
2
)
LPT-M-CL2
0 - 5.0 ppm
~3 years
Ethylene (C
2
H
4
)
LPT-M-C2H4
0 - 200 ppm
~2 years
Formaldehyde (CH
2
O)
LPT-M-CH2O
0 - 5.0 ppm
~2 years
Hydrogen (H
2
)
LPT-M-EH2
0 - 2,000 ppm ~2 years
Hydrogen Cyanide (HCN)
LPT-M-HCN
0 - 30 ppm
~2 years
Hydrogen Sulphide (H
2
S)
LPT-M-H2S
0 - 50 ppm
~2 years
Hydrogen Sulphide (H
2
S)
LPT-M-H2SB
0 - 50 ppm
~5 years
Nitric Oxide (NO)
LPT-M-NO
0 - 100 ppm
~2 years
Internal Electrochemical
Sensors continued...
Part Number
Range
Lifespan
Nitrogen Dioxide (NO
2
)
LPT-M-NO2A
0 - 10 ppm
~3 years
Nitrogen Dioxide (NO
2
)
LPT-M-NO2B
0 - 10 ppm
~6 years
Oxygen (O
2
)
LPT-M-O2
0 - 25% Vol
~3 years
Ozone (O
3
)
LPT-M-O3
0 - 1.0 ppm
~2 years
Sulphur Dioxide (SO
2
)
LPT-M-SO2
0 - 20 ppm
~2 years