Crestron
C2N-DB6/8/12
Decorator
Wall
Panels
Operations & Installation Guide - DOC. 6154
Decorator Wall Panels: C2N-DB6/8/12
•
19
Button Arrangement of C2N-DB Series Wall panels (Front Views)
press 1
press 2
press 3
press 4
press 5
press 6
press 1
press 2
press 3
press 4
press 5
press 6
press 7
press 8
press 1
press 2
press 3
press 4
press 5
press 6
press 7
press 8
press 9
press 10
press 11
press 12
The following table lists the symbol input and output signals,
respectively, and their functional descriptions.
NOTE
: All signals listed in the table are DIGITAL unless noted. A
digital signal can be high (logic level of 1) or low (logic level of 0), and
have rising edge (low to high) transitions, and falling edge (high to low)
transitions.
C2N-DB12 Symbol Signal Descriptions
SIGNAL
NAME
DESCRIPTION
Input
fbck1 thru fbck12
Activates feedback LEDs 1-12.
High/1=function feedback On
Low/0=function feedback Off
IndicatorIntensity
Controls LED indicator intensity.*
(analog)
Ramp Level=0-100% (If no signal is
connected, default is 100%.)
Output
press1 thru press12
Notifies control system of button press
(1-12).
*Sets LED value for
all
feedback indicators.
NOTE
: The join assignments for panels with fewer than 12 buttons and
feedback LEDs do not change.