MACHINE ALERTS
Alarms related with SmartSteam functionality
Alarm
Description
Cooler temp
recommended
If the SmartSteam temperature probe detects that the milk in the jug
is above 10ºC the warning will appear and the steaming cycle will not
start until cold milk is used. Using warm milk is a food-safety risk and
warm milk will not produce high quality foam.
SmartSteam clean due
If the programmed cleaning interval time for the SmartSteam (set
at five minutes by default) expires without the barista activating the
cleaning cycle manually, the barista must return the SmartSteam to
the down position. Then, 30 seconds later the machine will display
Steamer cleaning and start the cleaning pulses to flush the steamer.
Flush short, flush again
If the barista attempts at manual flush of the SmartSteam but
does not complete the full required flushing time as defined in the
programming, a warning will be displayed and the flushing must be
run again.
Alarms related with Group use
Alarm
Description
Group cleaning overdue
If the programmed daily cleaning interval time (set at 24 hours from
last cleaning by default) expires without the barista activating the
cleaning cycle manually, the warning will appear and will remain on
screen until the cleaning is completed. See “Group cleaning” section
for instructions on how to run the cleaning and reset the alarm.
Group over-use warning
Alarm to notice user that one of the groups is being used
excessively comparing to the others. When the total counter
(meaning all keys in all groups) reach the "Group overuse minimum"
parameter, it will see if one group is being used 1 to 3 times the rest
of groups installed. See “Group overuse” section for instructions
on how to reset the alarm. To prevent frequent overuse, it is best
to rotate using the double and single espresso portafilters between
group heads so that all groups get used more equally.
Alarms related with Maintenance
Alarm
Description
Water filter alarm
When the litres counter reaches 90% of ‘Water filter’ setting, this
alarm will be released.
Maintenance alarm
When the services counter reaches the ‘Service cycles’ setting, this
alarm will be released.