D I A M A N T
Pro
42
Original instructions.
USER PROGRAMMING
Cup warmer
1. Press the Cup Warmer button to enter the programming
menu and adjust the temperature you want your cups to
be warmed up between: Low, Mid or High
℃
℃
℃
℃
Use the following steps to program the cup warmer settings:
SmartSteam
1. Press the SmartSteam button
to enter the programming
menu.
2. Scroll using the arrows
to enter to the following
and adjust the following
parameters:
℃
℃
℃
℃
Use the following steps to program the SmartSteam settings:
SMART STEAM TEMP
65 C
SMARTSTEAM TEMPERATURE:
Temperature that the smart steam wand needs to reach before closing steam valve
FLUSH TIME:
Trigger to release auto-cleaning. If the steam wand hasn’t been used in the last 5-30 min (as chosen), and
the steam wand is in home position, it will start the auto-cleaning cycle. If not the “CLEANING
OVERDUE” alarm will be triggered.
SET AUTO FLUSH TIMER:
Time in which the steam valve (not pump) will open to perform auto-cleaning.
SET PUMP SPEED:
Speed that the peristaltic pump will be using, based in %PWM regulation.
SMARTSTEAM TEMP OFFSET:
Parameter to stablish difference between peristaltic pump and steam valve. Peristaltic pump will stop at
TSET-ST.OFFSET.