MACHINE ALERTS
Display messages and alarms
To alert users that routine service of the machine is due or against a situation that could possibly cause
damage to the machine, Diamant Pro has the following alerts programmed into its software:
℃
10:05
Friday, 24 March
Group cleaning overdue
118
℃
℃
℃
℃
℃
℃
℃
Note:
If one alarm is active, the warning icon (
) will be shown in the main display apart from the
alarm in the ‘Name’ filed.
If you press on the CREM logo area (
) on the main display, you will enter the alarm list
where you can see the alarms enabled (in case there are more than one at the same time).
i
Alarm description
Alarms related with grinding
Alarm
Description
GRX: Too fine
When the flowmeter is measuring less than ‘fine grinding’ setting, this
alarm will be released.
GRX: Too coarse
When the flowmeter is measuring less than ‘coarse grinding’ setting,
this alarm will be released.
GRX: Flowmeter
blocked
When the flowmeter is measuring 0ml for too long.
Alarms related with boiler filling
Alarm
Description
Filling timeout
If the steam boiler has been filling water for more than 180s, the
pump will stop and the display will show the alarm and the level icon