21
Peristaltic Pumps Series IP 100-800
IP 100/200
Note:
The following notes on installation apply for
pump series IP 100/200
5.2
Replacing the pumping hose
5.2.1 Removing the old pumping hose
1. Switch off the pump and secure it against
switching on, disconnect suction and
pressure side from the pipeline system.
Danger or burning
Before removing the pumping hose
allow the pump to cool down to
contact temperature.
2. Place a clean container under the pump to
catch lubrication fluid.
3. Unscrew plugs (2+3, Fig. 13) and let the
lubrication fluid run into the container.
1
3
2
Fig. 13
1
Cover fastening nuts
2
Oil filler bore with plug
3
Oil drain bore with plug
4. Unscrew 4 cover fastening nuts 1 (Fig. 13),
take off cover and O-ring and let the rest of
the sliding fluid flow into the container.
5. Unscrew both connecting sockets complete
with retaining flange and hexagon tube nuts
from the pump housing (Fig. 14) and pull
both connecting sockets out of the pumping
hose.
Fig. 14
Fig. 15
4 Ventilation pipe
6. Then remove the ventilation pipe (suction
side and pressure side) (Fig. 15).
Remove the retaining rings with Orings (hose)
from the pumping hose (Fig. 16).
7. Attach pump cover with O-ring and tighten
slightly with nuts.