31
Peristaltic Pumps Series IP 100-800
IP 400
Note:
The following notes on installation apply for
pumps series IP 400
5.8
Replacing the pumping hose
5.8.1 Removing the old pumping hose
1. Switch off the pump and secure it against
switching on, disconnect suction and
pressure side from the pipeline system.
Danger or burning
Before removing the pumping hose
allow the pump to cool down to
contact temperature.
2. Place a container under the pump to catch
the lubricating fluid.
3. Unscrew plugs (2+3, Fig. 33) and let the
lubricating fluid run into the container.
4. Unscrew 4 cover fastening nuts 1 (Fig. 33),
take off pump cover and O-ring and let the
Fig. 34
3
1
2
5. Unscrew both connecting sockets complete
with retaining flange and hexagon tube nuts
from the pump housing (Fig. 34) and pull
both connecting sockets out of the pumping
hose.
1 Cover fastening nuts
2 Oil filler bore with plug
3 Oil drain bore with plug
Fig. 33
rest of the lubricating fluid flow out of the
pump housing into the container.
Fig. 35
4 Ventilation pipe
4
Caution!