1. Switch off the pump and secure it against
restarting.
2. Drain off the lubricating fluid (see chapter
5.11.1)
3. Remove pump cover with O-ring.
4. Turn the rotor by hand until one sliding shoe
is free.
Fig. 59
5. Then the shims (Fig. 59) must be removed to
reduce the pumping pressure or additional
shims must be added to increase the
pumping pressure.
If shims are changed, you must make sure that
both sliding shoes are changed to the same
dimension. The measurements must comply
exactly with the table (see below).
6. Fasten the pump cover again with O-ring
(see chapter 5.11.3).
7. Replace the oil drain plug.
8. Refill with lubricating fluid.
9. Replace the oil fill plug.
Version with rotor design (up to 2000)
Pressure
Diameter - rotor
IP 600
IP 800
0 - 4 bar
543 mm
724 mm
4 - 6 bar
544 mm
726 mm
6 - 8 bar
547 mm
727 mm
8 - 10 bar
551 mm
728 mm
10 - 13 bar
552 mm
730 mm
Version with rotor design (from 2001)
Pressure
Diameter - rotor
IP 600
IP 800
0 - 2 bar
543 mm
722 mm
2 - 4 bar
543 mm
724 mm
4 - 6 bar
544 mm
725 mm
6 - 8 bar
547 mm
727 mm
8 - 10 bar
551 mm
728 mm
10 - 13 bar
552 mm
730 mm
Version with rotor design (up to 2000)
Pressure
Diameter - rotor
IP 600
IP 800
0-58 psi
21.38 inches
28.50 inches
58-87 psi
21.42 inches
28.58 inches
87-116 psi
21.53 inches
28.62 inches
116-145 psi
21.69 inches
28.66 inches
145-188,4 psi 21.73 inches
28.74 inches
Version with rotor design (from 2001)
Pressure
Diameter - rotor
IP 600
IP 800
0-29 psi
21.38 inches
28,43 inches
29-58 psi
21.38 inches
28.50 inches
58-87 psi
21.42 inches
28.54 inches
87-116 psi
21.53 inches
28.62 inches
116-145 psi
21.69 inches
28.66 inches
145-188,4 psi 21.73 inches
28.74 inches