Peristaltic Pumps Series IP 100-800
2.2
Intended use
The IP series of peristaltic pumps have been
designed and developed for stationary use and
permanent operation in industrial applications.
Pumps without explosion protected
drive must not be used in explosive
environments.
Pumping of the following substances is
prohibited:
•
combustible gases or vapours mixed with
air
•
combustible fluids of danger class A + B,
acc. to VbF
•
combustible, fluid substances of class III a
(appendix C to EVO)
•
Fluids with ignition temperatures below
200
°
C/360
°
F must not even be pumped with
explosion protected pumps.
Before using the pump for food applications
make sure that all product contacting pump parts
have been approved for food.
All normal hygienic requirements for the
pumping of foodstuff must be strictly observed.
2.3
Unintended use
The operating safety and reliability of the
supplied pump can only be assured if it is used
for the purpose it is intended for. The limits
mentioned in the technical data sheet must not
be exceeded under any circumstances.
2.4
Operation of pump
The pump must only be operated by trained,
instructed and authorized persons. Any
responsibilities must be clearly appointed before
starting operation and should always be
complied with.
Strictly observe the operating instructions for the
pump drive unit.
2. Safety
2.1
General
Make sure that the pump is installed in
compliance with all applicable national safety
regulations.
Always observe all applicable accident
prevention instructions and implementing
regulations.
The following precautions must be applied
before performing maintenance work.
If the product to be pumped is a hazardous or
noxious substance, the system must be
neutralized and vented
Danger!
Depending on operating conditions
the pump may reach temperatures
too high to touch. You should
therefore switch off the pump and
let it cool down before touching it.
• Disconnect main drive unit and pump from the
electric power supply and isolate/lock-out.
• Depressurize the pump head.
It is not permitted to run the pump after
removing the pump cover. When cleaning the
pump manually make sure that all necessary
precautions have been applied.
All incorrectly installed, unprofessionally
operated or insufficiently serviced machines
and pumps are potential safety hazards.
The non-observance of relevant safety
measures may cause injury to operating
personnel or damage to the pump. Guards
must be properly assembled again before
restarting. The pump must be shut down or
should not be restarted if any defects are found
which could affect the operating safety and
reliability of the pump.
Hazard!
Caution!