10
ASSEMBLY
Figure 10
Figure 11
If you experienced resistance rolling the unit, either when repositioning
the shift lever from 6 to R2 or when attempting to move the machine
with the drive control released, adjust the drive control immediately. To
adjust, proceed as follows:
• Loosen the nylock nut on the drive control cable and unthread the
cable one full turn. See Figure 10.
• Recheck adjustment.
• Retighten the nylock nut to secure the cable when correct adjust-
ment is reached.
NOTE:
For more details, refer to Drive Control Adjustment in the
Adjustment Section of this manual.
Auger Control
Check the adjustment of the auger control as follows:
• When the auger control is released and in the disengaged “up”
position (see Figure 9), the cable should have very little slack, but
should NOT be tight.
WARNING:Do not over-tighten the cable. Over-
tightening may prevent the auger from disengaging
and compromise the safety of the snow thrower.
• In a well-ventilated area, start the snow thrower engine as instruct-
ed on page 12. Make sure the throttle is set in the fast position.
• While standing in the operator’s position (behind the snow thrower)
engage the auger.
• Allow the auger to remain engaged for approximately ten seconds
before releasing the auger control. Repeat this several times.
• With the engine running in the fast position and the auger control
lever in the disengaged “up” position, walk to the front of the
machine.
• Confirm that the auger has completely stopped rotating and shows
no signs of motion.
IMPORTANT: If the auger shows any signs of rotating, immediately
return to the operator’s position and shut off the engine. Wait for all
moving parts to stop before readjusting the auger control cable.
• To readjust the control cable, unhook the spring (found on the end
of the auger cable) from the auger actuator bracket. See Figure 10.
• Push the cable coupler through the end of the spring to expose the
lock nut. See Figure 11.
• Thread the nylock nut outward (down the coupler) three full turns
to provide more slack in the cable and reattach the spring to the
bracket.
• Repeat auger control test to verify for proper adjustment. Repeat
previous steps to adjust more, if necessary.
Содержание C459-52833
Страница 2: ...2 199260 07 21 05 BY Printed in U S A 02488 ...
Страница 23: ...NOTES 23 ...
Страница 33: ...NOTES 33 ...
Страница 34: ...NOTES 23 ...