background image

1

 Bind Screw 5x25

2

 Filter Cover

Lock flip of Filter Cover

3

 Filter Element

4

 Upper Case

5

 Gasket C

6

 Hex Bolts 5x16

7

 Cylinder Cover

8

 Gasket A

9

 Cylinder

0

 Piston Set

A

 Blower Body

B

 Hex Bolts 5x25

D

 Lead Wire

E

 Connector A

F

 Middle Case

H

 Gasket B

Air Outlet 

U-shaped groove 

Never loosen Hex Bolts 5x30 (2 pcs.)

Wiring guide No.1

Gasket Air Cleaner 

Lead Wire Bushing (black)

Screwdriver blade slot 

Side holes 

Screwdriver blade slot 

G

 Connector B

Hooks 

Corresponding

latches 

I

 Bottom Case

C

 Silicon Hose

Connector holder

Screwdriver blade slot 

View A 

J

 Bind Screw 5x14

Wiring guide No.2

Wiring guide No3

Exploded View (LA-60ECO) 

Models

Parts No.

Parts Name

Q’ty

LB08038

Piston Set

1

1

1

LQ06685

Gasket A

LA-60ECO

LQ06856

Filter Element

Spring Seat (With Ball) 

Applied Grease 

Fixing of Spring 

Sliding part (Brown) 

Sliding part (Brown) 

Cap 

Piston 

Spring 

Cautions

Gasket A 

Blower Body 

How to mount 

Protruding portions

Cross-Section View of Piston Set 

Instruction of Gasket A  

Attach Gasket A so the four 
protruding sections face the 
blower body and carefully 
located into its corresponding 
slots. 
If these protruding sections are 
not correctly located into the 
slots, air leakage will result.

If detached, re-fit the spring into the back 
of the piston by rotating it anti-clockwise
Remove the plastic cap before use. This 
cap is used to protect the special grease 
prior to fitting.
Never apply additional grease as this will 
likely cause damage or malfunction

1. Cautions 

2. Replacement of Filter Element

MEDO LA-ECO BLOWER MAINTENANCE MANUAL

LA-60ECO

Explanation of Diagrammatic Expressions

(1)  MEDO blowers are OILLESS. Never lubricate them.
(2) The 

A

 Blower Body has already been precisely adjusted. Never disassemble.

(Never loosen Hex Bolts 5x30 (2 pcs.) on the rear of 

A

 Blower Body.)

This instruction manual should be read and understood 
thoroughly before any maintenance work is executed.

The term “Attention” as used in this manual is to alert you to dangers such as the following;

The degree of Danger Indicated by “Attention” clauses.

Clause

ATTENTION

Such clauses indicate the possibility that continuing to work 
while ignoring the “Attention” clause, or working with 
negligence, may cause personal injury or property damage.

(1)  Be sure to unplug the blower before starting any work.
(2)  If present, unscrew the 

J

 Bind Screw 5x14, and push the catch to open the 

2

 Filter Cover.

(3) Remove 

the 

3

 Filter Element from 

4

 Upper Case and replace with a new one.

At the same time, clean the air inlet of 

2

 Filter Cover and 

4

 Upper Case.

(4)  Verify that Gasket Air Cleaner is correctly fitted to 

4

 Upper Case.

(5) Return 

3

 Filter Element to 

4

 Upper Case.

(6)  Follow Instruction Label affixed to 

2

 Filter Cover and lock 

2

 Filter Cover with 

4

 Upper 

Case by pushing within the dotted line area until Filter Cover lock audibly clicks into place.

(7) Tighten 

J

 Bind Screw 5x14.

(8)  Filter Element Replacement Period.

It is recommended that the Filter Element(s) be cleaned or replaced with a new one(s)
depending on the extent of its deterioration as determined by the atmospheric conditions
around the installation point. Filter Element(s) should be checked every three months.
Replace Filter Element only with a genuine NITTO KOHKI part. Otherwise there is a risk
of damage or malfunction.

3. Replacement of Piston Set

(1)  Be sure to unplug the blower before starting any work.
(2) Unscrew 

the 

1

 Bind Screw 5x25 of 

4

 Upper Case with cross slot screwdriver and remove 

4

 Upper Case.

(3) Disconnect 

C

 Silicon Hose from the wiring guide No.2.

(4)  While pressing the fastening clip of 

E

 Connector A, pull it up to remove it from 

F

 Middle 

Case.

(5) Remove 

G

 Connector B from 

F

 Middle Case by pushing 

G

 Connector B down.

(6) Unscrew 

B

 Hex Bolts 5x25 (4 pcs.) from the four corners of 

F

 Middle Case using a cross 

slot screwdriver and remove 

F

 Middle Case. If it is tight and hard to remove, insert a flat

screwdriver into the screwdriver blade slot on 

F

 Middle Case and carefully pry it open.

(7) Unscrew 

the 

6

 Hex Bolts 5x16 (4 pcs.) in the 

7

 Cylinder Cover using a  cross slot 

screwdriver or socket wrench and remove the 

7

 Cylinder Cover.

If it is tight and hard to remove, insert a flat screwdriver into the slot between 

A

 Blower 

Body and 

7

 Cylinder Cover and carefully pry it open.

(8) Pull 

out 

9

 Cylinder and 

0

 Piston Set from 

A

 Blower Body in this order.

(9) Replace 

0

 Piston Set and 

8

 Gasket A with new one. Take extreme care that there is no

dust, oil or other contamination on the sliding part (brown) of 

0

 Piston Set.

Avoid touching the sliding part as much as possible. Also observe the precautions noted 
next to the Cross-Section View of Piston set.

(10) Insert the 

0

 Piston Set into the 

A

 Blower Body and mount 

8

 Gasket A onto 

A

 Blower 

Body following the instruction noted next to the Instruction of Gasket A so that the side 
holes of 

9

 Cylinder are oriented towards the both sides (left and right).

(11) Attach the 

7

 Cylinder Cover to the 

A

 Blower Body being careful not to shift 

8

 Gasket A 

then tighten 

6

 Hex Bolts 5x16 (4 pcs.) with a cross slot screwdriver or socket wrench.

Tighten the bolts evenly little by little and finish up by tightening them securely.

(12) Place the 

F

 Middle Case back onto the 

A

 Blower Body. Insert the Lead Wire Bushing 

(black) into the U-shaped groove on 

F

 Middle Case ensuring a snug fit, and then tighten 

B

 Hex Bolts 5x25 (4 pcs.) in the four corners of 

F

 Middle Case with a cross slot 

screwdriver.

(13) Insert 

G

 Connector B into the connector holder of 

F

 Middle Case and establish a secure 

connection with 

E

 Connector A.

(14) Insert the 

D

 Lead Wire into the wiring guides No.1 and No.2 on 

F

 Middle Case in this 

order, and fix 

D

 Lead Wire with 

C

 Silicon Hose.

(15) After inserting the 

D

 Lead Wire into the wiring guides No.3, carefully locate it inside the 

guide of 

H

 Gasket B. Re-locate the remaining length of the 

D

 Lead Wire back into its 

adjacent slot within the 

I

 Bottom Case.

(16) Connect the Power Supply before replaceing the 

4

 Upper Case and make a trial operation.

Block up Air Outlet with your hand to ensure there are no air leak.
If there is an air leak, remove 

F

 Middle Case, and retighten 

6

 Hex Bolts 5x16 (4 pcs.) 

which tighten 

7

 Cylinder Cover evenly and tightly, or verify that 

8

 Gasket A is properly 

mounted following the instruction noted next to the Instruction of Gasket A.

(17) Be sure to unplug the blower after finishing a trial operation.
(18) Verify that 

5

 Gasket C is properly mounted.

(19) Engage the hooks of 

4

 Upper Case into the corresponding latches on 

I

 Bottom Case, 

place the 

4

 Upper Case onto the 

I

 Bottom Case.

(20) After making sure that the 

4

 Upper Case and 

I

 Bottom Case are seated properly, tighten 

1

 Bind Screw 5x25 using a cross slot screwdriver.

Safety and Operating Instructions

Safety Instructions

Contents of Repair Parts Kit

ATTENTION

The Meanings of the Symbols

Symbols

This symbol advises you of an item which should 

BE NOTED

 (including 

Danger or Warning). Accompanying notes may include a picture or 
explanatory text inside the triangle or next to the symbol mark

This symbol advises you of an action which must 

NOT BE TAKEN (IS 

PROHIBITED)

 in order to avoid danger. The general actions which must 

not be taken will be shown by a picture or explanatory text inside or next to 
the symbol mark.

This symbol advises you of an action which 

must BE TAKEN (IS MANDA-

TORY)

 in order to avoid danger. The action which must be taken will be 

shown by a picture or explanatory text inside the circle or next to the 
symbol mark.

The following safety precautions should always be followed to reduce the risk of breakdown 
and/or accidents.

• • • To Prevent Electric Shock And Fire

1

  Don’t install the blower where it may be flooded with water and buried in snow.

2

  Electric work must be done by a qualified electrician.

3

  The power supply should be the rated voltage shown on the label on the blower and 

be fitted with earth leakage and over current breakers. 

4

  The power outlet used should be waterproof and include an earth connected to the 

ground.

5

  If the power supply cord is damaged, it must be replaced by the manufacturer or its 

service agent or similarly qualified person in order to avoid a hazard.

6

  Don’t place any objects on the power supply cord.

7

  Be sure to unplug the blower before starting maintenance.

8

  Be sure to replace the Upper Case and Filter Cover after maintenance.

9

  Check for dust on the electric plug and clean it at least once a year.

Ignoring any of the above 

1

-

9

 may cause an electric shock or a fire.

0

  Don’t touch the metal part of the blower until it has cooled down as the blower runs 

very hot.

Ignoring the above 

0

 may cause a burn.

LQ07306-0

LQ07306-0

Отзывы: