Troubleshooting
CLS
Advance
Error code Description/Cause
Category
Remedy/hints
By whom
0x8E6C
Coin input funnel master
inhibit set
Info
0x8E6D
Coin input funnel was reset
Info
0x8E6E
Coin(s) detected in coin input
funnel. CLS started operation
Info
0x9123
Main PCB firmware bundle
version mismatch
Attention
FW file failure, contact service
Service
0x9164
CLS control unit retrying
communication after unsuc-
cessfully attempting to com-
municate with Main PCB
Info
0x9166
Main PCB replied with NACK
status code after sending
Main PCB a command
Info
0x9167
Main PCB replied with BUSY
status code after sending
Main PCB a command
Info
0x9168
Main PCB replied with wrong
checksum
Info
0x9169
Main PCB replied with
unknown command
Info
0x916A
Main PCB replied with not
allowed
Info
0x916B
Main PCB replied with bad
parameter
Info
0x91CC
Main PCB is entering boot
loader mode
Info
0x91CD
Main PCB is exiting boot
loader mode
Info
0x91CE
Main PCB sent ACK for
command "verify CRC and
set OK"
Info
0x91CF
Main PCB sent ACK for com-
mand "write data to buffer"
Info
0x91D0
Main PCB sent ACK for
command "compare buffer
with flash"
Info
0x91D1
Main PCB sent ACK for com-
mand "prepare sector"
Info
0x91D2
Main PCB sent ACK for com-
mand "erase sector"
Info
Error code Description/Cause
Category
Remedy/hints
By whom
0x91D3
Main PCB sent ACK for com-
mand "copy buffer to flash"
Info
10.2.2.2
Error codes transmitted by the CLS coin validator
Error code
Description/Cause
Category
Remedy/hints
By whom
0x0001
Coin validator disabled by
control software
Info
If unintended, configuration
failure, contact service
Service
0x1000
Coin validator was reset
Info
0x2010
Coin jam in measurement area
or sensors covered
Attention
• Eliminate jam/foreign
object
nating coin jam in acceptance
unit", p. 38)
• Cleaning, contact service
• Attendant possessing
the key for the upper/
lower lock
• Service
0x2015
Centrifuge blocked and cannot
turn forward or backword
Attention
• Eliminate jam/foreign
object
nating coin jam in acceptance
unit", p. 38)
• Cleaning, contact service
• Attendant possessing
the key for the upper
lock/lower lock
• Service
0x2016
Coin transport belt blocked
Attention
• Eliminate jam/foreign
object
nating coin jam in acceptance
unit", p. 38)
from belt
• Cleaning, contact service
• Attendant possessing
the key for the upper
lock/lower lock
• Service
0x2018
Measurement timeout during
measurement
Info
If necessary, Eliminate jam/
foreign object
Eliminating coin jam in acceptance
unit", p. 38)
Attendant possessing
the key for the upper/
lower lock
0x2019
Measurement timeout during
compensation
Info
If necessary, Eliminate jam/
foreign object
Eliminating coin jam in acceptance
unit", p. 38)
Attendant possessing
the key for the upper/
lower lock
0x2020
Operating voltage low
Critical
• Make sure that CLS is
connected correctly
Chap. "6.4 Putting the CLS into
service", p. 24)
• Connection failure, contact
service
• Attendant
• Service
0x2021
Operating voltage high
Critical
• Make sure that CLS is
connected correctly
(cf.
Chap. "6.3 Putting the CLS into
service", p. 47)
• Connection failure, contact
service
)
• Attendant
• Service