
Product characteristics and specifications
1-2
Coway co., Ltd
1-1-1 Major Part Characteristics
Part Name
FEED valve / NOS valve (for safety cutoff)
Use
Source water entry and safety cutoff function
Operation
principles
Opens and closes the flow path when full water signals from the low water level/full
water level sensor and overflow sensor are detected to stop entry of source water
in two ways.
Part Name
Low water level / Medium water level / Full water level sensor (capacitance sensor)
Use
Water level detection in the room-temperature water tank
Operation
principles
Detects the room-temperature water tank level in three stages and adjusts room-
temperature water operation through the FEED valve.
Part Name
Overflow sensor (capacitance sensor)
Use
Water level detection in the room-temperature water tank
Operation
principles
Operates the NOS valve to cut off room-temperature water when the water
overflow sensor detects an overflow in the room-temperature water tank.
Major Part Characteristics
Parts
Standard ratings and specifications
Remarks
Feed Valve / NOS Valve
• Volts : DC 24 V
• AMPS : 210 mA
Compressor
• Refer to the rating plate.
Содержание CHP-671R/L
Страница 1: ...CHP 671R L...
Страница 2: ......
Страница 8: ...MEMO 1 4 Coway co Ltd...
Страница 16: ...MEMO 2 8 Coway co Ltd...
Страница 32: ...MEMO 3 16 Coway co Ltd...
Страница 53: ...MEMO Coway co Ltd 4 21...
Страница 64: ...MEMO 6 8 Coway co Ltd...
Страница 66: ...Reference information 7 2 Coway co Ltd Rear Top Cover Rear Cover Power Cord Outlet Blue CHP 671R L Inlet Orange...
Страница 73: ...MEMO Coway co Ltd 7 9...
Страница 74: ...MEMO 7 10 Coway co Ltd...