Fault diagnosis
4-10
Coway co., Ltd
HOT control function (heater control)
Function
Explanation
1.
Heater control
function
• If the HOT selection switch is ON, the heater is controlled according to water level
and hot water temperature.
- Heater ON temperature: 80 °C (26.13 kΩ): revision (previously 84 °C)
- Heater OFF temperature: 94 °C (16.302 kΩ)
• HOT selection switch ON
- The HOT function is selected if the HOT selection switch is pressed briefly
(200 ms or more).
- Heater output is controlled according to water level and hot water temperature
after the HOT selection switch is ON for 1 second.
- The heater only operates if low water level is detected. The heater does not
operate if there is a water level sensor error or low water level is not detected.
- FND display status
→
H1 always kept ON, H2/H3 ON/OFF control according to hot water
temperature
• HOT selection switch OFF
- The HOT function is turned off if the HOT selection switch is pressed and held
(1s or more).
- Heater output is turned OFF after the HOT selection switch is OFF.
- FND display status
→ H1/H2/H3 kept off
• FND display control specifications according to hot water temperature are as
follows.
- ON/OFF control specifications according to the HOT segment's temperature are
as follows.
HOT Segment
ON
OFF
H3
94 °C (16.302 kΩ)
80 °C (26.13 kΩ)
H2
79 °C (27.06 kΩ)
74 °C (32.292 kΩ)
H1
Always ON
- Temperature detection range: 1.2 MΩ ~ 13 kΩ
Содержание CHP-671R/L
Страница 1: ...CHP 671R L...
Страница 2: ......
Страница 8: ...MEMO 1 4 Coway co Ltd...
Страница 16: ...MEMO 2 8 Coway co Ltd...
Страница 32: ...MEMO 3 16 Coway co Ltd...
Страница 53: ...MEMO Coway co Ltd 4 21...
Страница 64: ...MEMO 6 8 Coway co Ltd...
Страница 66: ...Reference information 7 2 Coway co Ltd Rear Top Cover Rear Cover Power Cord Outlet Blue CHP 671R L Inlet Orange...
Страница 73: ...MEMO Coway co Ltd 7 9...
Страница 74: ...MEMO 7 10 Coway co Ltd...