Fault diagnosis
Coway co., Ltd
4-15
Function
Explanation
6.
COOL
temperature
fine control
function
(hardware)
• C/T UP function
- The C/T UP jumper is cut to increase the control temperature 0.5 °C (
≒
3.0 kΩ).
COOL Segment
ON
OFF
C3
6.2 °C
(120.138 kΩ)
8.3 °C
(108.747 kΩ)
C2
9.5 °C
(102.786 kΩ)
12.0 °C
(91.509 kΩ)
C1
Always ON
- Temperature detection resistance range: 160.0 kΩ ~ 12 kΩ
• C/T DOWN function
- The C/T DOWN jumper is cut to decrease the control temperature 0.5 °C
(
≒
3.0 kΩ).
COOL Segment
ON
OFF
C3
5.7 °C (123.045 kΩ)
7.8 °C (111.344 kΩ)
C2
9.0 °C
(105.224 kΩ)
11.5 °C
(93.649 kΩ)
C1
Always ON
The above data may vary depending on the method of calculation with figures by
simple computation.
- Temperature detection resistance range: 163 kΩ ~ 13 kΩ
7.
Other
• Cold water temperature thermistor model: MLT-50B
• Thermistor temperature detection error range: ± 0.5 °C or less
• The cold water temperature sensing circuit's partial pressure resistance is D grade
(0.5 %).
• The cold water temperature is checked 100 times and, if it is within a set range at
those 100 times, the temperature is detected as normal.
• Cold water temperature detection range: 0 °C ~ 55 °C (
≒
163 kΩ ~ 15 kΩ)
Содержание CHP-671R/L
Страница 1: ...CHP 671R L...
Страница 2: ......
Страница 8: ...MEMO 1 4 Coway co Ltd...
Страница 16: ...MEMO 2 8 Coway co Ltd...
Страница 32: ...MEMO 3 16 Coway co Ltd...
Страница 53: ...MEMO Coway co Ltd 4 21...
Страница 64: ...MEMO 6 8 Coway co Ltd...
Страница 66: ...Reference information 7 2 Coway co Ltd Rear Top Cover Rear Cover Power Cord Outlet Blue CHP 671R L Inlet Orange...
Страница 73: ...MEMO Coway co Ltd 7 9...
Страница 74: ...MEMO 7 10 Coway co Ltd...