Fault diagnosis
4-14
Coway co., Ltd
Function
Explanation
4.
Compressor
operation
delay time
function
• The compressor starts 5 minutes after the point at which COOL selection mode
was ON.
• If the power is turned ON again after being stopped while the COOL selection
mode was ON, the compressor starts after 5 minutes.
• If it is restored and operates normally after a cold water temperature sensor error
or overcooling while the COOL selection mode is ON, the compressor starts 5
minutes after it had stopped.
5.
Cooling delay
safety blocking
function
• The cooling delay safety blocking function operates as follows.
- If the compressor operates continuously for 150 minutes, its output is turned
OFF for 5 minutes regardless of cold water temperature to prevent overcooling
or ice formation.
- After the compressor's output is OFF for 5 minutes, it restarts according to cold
water temperature.
- If 6.5 °C or less is detected while the compressor has operated for 130 minutes
or more, output is stopped.
• After the compressor's output is OFF for 5 minutes, it restarts according to cold
water temperature control specifications.
- When the cold water temperature control specifications are ON temperature
(7.8 °C) or more, the compressor starts.
- If the cold water temperature control specifications are between ON temperature
(7.8 °C) and OFF temperature (5.7 °C), the compressor does not start.
Содержание CHP-671R/L
Страница 1: ...CHP 671R L...
Страница 2: ......
Страница 8: ...MEMO 1 4 Coway co Ltd...
Страница 16: ...MEMO 2 8 Coway co Ltd...
Страница 32: ...MEMO 3 16 Coway co Ltd...
Страница 53: ...MEMO Coway co Ltd 4 21...
Страница 64: ...MEMO 6 8 Coway co Ltd...
Страница 66: ...Reference information 7 2 Coway co Ltd Rear Top Cover Rear Cover Power Cord Outlet Blue CHP 671R L Inlet Orange...
Страница 73: ...MEMO Coway co Ltd 7 9...
Страница 74: ...MEMO 7 10 Coway co Ltd...