Fault diagnosis
4-16
Coway co., Ltd
Water level display function (capacitance water level detection equipment)
Function
Explanation
1.
Types of water
level detection
sensors
• Low water level/medium water level/full water level/water overflow detection
sensor: capacitance IC used (Chemtronics)
2.
Sensor
detection
conditions
• If the water level sensor input is maintained equivalently for 3 seconds [1 second in
test mode], normal operation is detected
• If the water overflow sensor is maintained for 20 seconds or more, water overflow
is detected
3.
Display
operation
• Water overflow detection status
: Water sensor FND (L1, L2, L3) 0.5 second ON/OFF periodic flashing.
• Water level sensor malfunction
- Low water malfunction: Low water FND (L1) 0.5 second ON/OFF periodic
flashing. L2, L3 FND are off.
- Medium water malfunction: Medium water FND (L2) 0.5 second ON/OFF
periodic flashing. L1, L3 FND are off.
- Full water malfunction: Full water FND (L3) 0.5 second ON/OFF periodic
flashing. L1, L2 FND are off.
- Dual water level error: (Low water/medium water/full water) error + water
overflow error, low water + medium water FND (L1 + L2)
0.5 second ON/OFF periodic flashing. L3 FND is off.
- If water overflow is detected 3 times or more, an overflow-related error is
indicated on the display and the related valve stops operating.
Содержание CHP-671R/L
Страница 1: ...CHP 671R L...
Страница 2: ......
Страница 8: ...MEMO 1 4 Coway co Ltd...
Страница 16: ...MEMO 2 8 Coway co Ltd...
Страница 32: ...MEMO 3 16 Coway co Ltd...
Страница 53: ...MEMO Coway co Ltd 4 21...
Страница 64: ...MEMO 6 8 Coway co Ltd...
Страница 66: ...Reference information 7 2 Coway co Ltd Rear Top Cover Rear Cover Power Cord Outlet Blue CHP 671R L Inlet Orange...
Страница 73: ...MEMO Coway co Ltd 7 9...
Страница 74: ...MEMO 7 10 Coway co Ltd...