C
No
No
Yes
Yes
No
Fault diagnosis
4-6
Coway co., Ltd
Malfunction if heater
resistance is 0 Ω, ∞
Bimetal current flow normal
Check and replace heater
Check and replace bimetal
Faulty MAIN PBA
Check and replace MAIN PBA
Is the heater resistance
88 Ω + 1.5 % - 8 %?
Is the bimetal normal?
Is the voltage supplied
to the heater rated voltage when
the heater is on?