Fault diagnosis
Coway co., Ltd
4-17
No.
Sensor status
Display (LED)
Valve operation
Malfunction
information
Normal
restoration
Low
water
Medium
water
Full
water
Over
Low
water
Medium
water
Full
water
Feed
NOS
1
Detected Detected Detected
Not
detected
ON
ON
ON
Close
Open
Normal - full water
Restored
when error
canceled
2
Detected Detected
Not
detected
Not
detected
ON
ON
OFF
Open
Open
Normal - re-purification -
water level increase
3
Detected Detected
Not
detected
Not
detected
ON
ON
OFF
Close
Open
Normal - re-purification -
water level decrease
Full water level → valve
operation after medium
water level 30 minutes
4
Detected
Not
detected
Not
detected
Not
detected
ON
OFF
OFF
Open
Open
Normal
5
Not
detected
Not
detected
Not
detected
Not
detected
OFF
OFF
OFF
Open
Open
Normal
6
Detected
Not
detected
Detected
Not
detected
OFF
Blink
OFF
Close
Open
Medium water level
detection malfunction
7
Not
detected
Not
detected
Detected
Not
detected
OFF
OFF
Blink
Close
Open
Full water level detection
malfunction
8
Not
detected
Detected
Not
detected
Not
detected
Blink
+
OFF
OFF
+
Blink
OFF
Close
Open
Low/medium water level
detection malfunction
9
Not
detected
Detected Detected
Not
detected
Blink
OFF
OFF
Close
Open
Low water level detection
malfunction
10
Detected Detected Detected Detected
Blink
Blink
Blink
Close
Close
Water supply valve
malfunction
Power
reinserted
11
Not
detected
Not
detected
Not
detected
Detected
Water overflow sensor
detection malfunction
12
Detected Detected
Not
detected
Detected
OFF
OFF
Blink
Close
Close
Full water level /
overflow error (dual error)
13
Detected
Not
detected
Detected Detected
Blink
Blink
OFF
Close
Close
Sensor detection
malfu
water overflow error
14
Detected
Not
detected
Not
detected
Detected
15
Not
detected
Not
detected
Detected Detected
16
Not
detected
Detected
Not
detected
Detected
17
Not
detected
Detected
Not
detected
Detected
The #10 error is displayed when it occurs 3 times in total and operation is normal if over/full water level is canceled.
Even 3 times in total can be cleared.
Содержание CHP-671R/L
Страница 1: ...CHP 671R L...
Страница 2: ......
Страница 8: ...MEMO 1 4 Coway co Ltd...
Страница 16: ...MEMO 2 8 Coway co Ltd...
Страница 32: ...MEMO 3 16 Coway co Ltd...
Страница 53: ...MEMO Coway co Ltd 4 21...
Страница 64: ...MEMO 6 8 Coway co Ltd...
Страница 66: ...Reference information 7 2 Coway co Ltd Rear Top Cover Rear Cover Power Cord Outlet Blue CHP 671R L Inlet Orange...
Страница 73: ...MEMO Coway co Ltd 7 9...
Страница 74: ...MEMO 7 10 Coway co Ltd...