Fault diagnosis
Coway co., Ltd
4-19
Temperature level setting function (hidden function) - hot water temperature level
setting mode added for export
Function
Explanation
1.
Temperature
LEVEL setting
function
• If power is connected and the HOT selection switch is pressed within 5 seconds
after the FND flashes twice, LEVEL setting mode is entered.
- If the selection switch is pressed after initial power connection, test mode is not
entered.
• If the temperature LEVEL setting mode is entered, both compressor/heater
operation controlled by the MAIN PBA are stopped.
• Temperature setting cold/hot water FND both flash.
– Initially, [factory settings] set at stage 3.
• Each time the HOT selection switch is pressed (1 second or more), changes in the
order of H1/H2/H3 → H1/H2 → H1 → H1/H2/H3.
HEATER control temperature according to temperature LEVEL is as follows.
HOT LEVEL
Heater OFF
Heater ON
Remarks
H1/H2/H3
flashing
94 °C (16.302 kΩ)
80 °C (26.13 kΩ)
Stage 3
[Korean
temperature]
H1/H2 flashing
90 °C (18.599 kΩ)
85 °C (22.003 kΩ)
Stage 2
H1 flashing
84 °C (22.766 kΩ)
79 °C (27.060 kΩ)
Stage 1
Содержание CHP-671R/L
Страница 1: ...CHP 671R L...
Страница 2: ......
Страница 8: ...MEMO 1 4 Coway co Ltd...
Страница 16: ...MEMO 2 8 Coway co Ltd...
Страница 32: ...MEMO 3 16 Coway co Ltd...
Страница 53: ...MEMO Coway co Ltd 4 21...
Страница 64: ...MEMO 6 8 Coway co Ltd...
Страница 66: ...Reference information 7 2 Coway co Ltd Rear Top Cover Rear Cover Power Cord Outlet Blue CHP 671R L Inlet Orange...
Страница 73: ...MEMO Coway co Ltd 7 9...
Страница 74: ...MEMO 7 10 Coway co Ltd...