87
60T - 280T
COSMOGAS
19 - FORCED MENU
Boiler parameters
Water heater parameters
Ref.
Parameter description
Adjustment range
Default
value
Individual burner
(mod. 60T and
70T)
Burner 1 (Master)
(mod. 100T,
115T, 140T, 180T,
210T and 280T)
Burners from
2 to 4
(mod. 100T,
115T, 140T, 180T,
210T and 280T)
Individual burner
(mod. 60T and
70T)
Burner 1 (Master)
(mod. 100T, 115T,
140T, 180T, 210T
and 280T)
Burners from
2 to 4
(mod. 100T, 115T,
140T, 180T, 210T
and 280T)
Customised
values
3001 Burner operation address
0 = Not in cascade
1 = Burner 1 (Master),
2 to 4 = Burner from 2 to 4 (slave burners)
2
0
1
from 2 to 4
0
1
from 2 to 4
3002 Fan adjustment range
from 0 to 4
0
60 = 0
70 = 2
100 and 115 = 0
140, 180, 210 and 280 = 2
60 = 0
70 = 2
100 and 115 = 0
140, 180, 210 and 280 = 2
3003 Display unit of measurement
C = °C and bar;
F = °F and PSI;
C
C
C
C
C
C
C
3004 Water pressure switch
0 = Disabled; 1 = Enabled;
2 = N/A; 3 = N/A
1
1
1
0
1
1
0
3005
Burner flapper valve
0 = Disabled; 4 = Enabled;
8 = N/A; 12 = N/A
4
0
4
4
0
4
4
3006
Water flow rate sensor
0 = Disabled; 16 = N/A;
32 = N/A; 48 = Enabled
48
48
48
48
48
48
48
3007 Condensate level sensor
EnAb = Enabled;
dISA = Disabled
Enab
Enab
Enab
dISA
Enab
Enab
dISA
3008 Combustion gas sensor type
SEnS = Sensor; StCH = Switch
SEnS
SEnS
SEnS
SEnS
SEnS
SEnS
SEnS
3009 External sensor type
10 = 10kohms; 12 = 12kohms;
10
10
10
10
10
10
10
3010 Other sensor type
10 = 10kohms; 12 = 12kohms;
10
10
10
10
10
10
10
3011
pump mode
0 = main c pump; 1 = N/A;
2 = N/A; 3 = N/A;
0
0
0
0
0
0
0
3012 domestic hot water operating mode
0 = only heating;
1= hot water storage tank;
2 = storage tank with
thermostat;
3 = N/A; 4 = N/A; 5 = N/A
0
0 = only
heating;
1= hot water
storage tank;
0 = only
heating;
1= hot water
storage tank;
0
0 = only
heating;
1= hot water
storage tank;
0 for
instantaneous
domestic hot
water;
1 per hot water
storage tank.
0
3013 Reset Err 115
EnAb = Enabled;
dISA = Disabled
Enab
Enab
Enab
Enab
Enab
Enab
Enab
3015 Climatic adjustment: heating supply
maximum temperature (this parameter
is overwritten by parameter 3017)
from 20°C to 90°C
82°C
82°C
82°C
82°C
N/A
N/A
N/A
3016 Climatic adjustment: heating supply
minimum temperature
from 20°C to 90°C
20°C
20°C
20°C
20°C
N/A
N/A
N/A
3017 Supply maximum temperature (this
parameter takes priority with respect to
parameter 3015)
from 20°C to 90°C
82°C
82°C
82°C
82°C
82°C
82°C
82°C
3018 Minimum supply temperature
from 20°C to 90°C
32°C
32°C
32°C
32°C
32°C
32°C
32°C
3020
Water flow rate sensor type
0 = N/A; 1 = DN8;
2 = DN 10; 3 = DN 15;
4 = DN 20; 5 = DN 25
3
4
4
4
4
4
4
3022 Water minimum pressure
from 0 to 5 bar
1
1
1
1
1
1
1
3035
Minimum water flow rate
from 0 to 100 l/min
27
27
27
27
27
27
27
3050 Slave burner number
from 0 to 3
3
3
100, 115 and
140 = 1
210 = 2
280 = 3
3
3
100, 115 and
140 = 1
210 = 2
280 = 3
3
3085 Modbus address
0 to 126
1
1
1
1
1
1
1
3086 Number of Stopbits
1 or 2
1
1
1
1
1
1
1
3100 Material selection
ABS; CPVC; PVC; SST; PP.
PVC
PVC
PVC
PVC
PVC
PVC
PVC
3101 Nation Selection
US, CA
US
US
US
US
US
US
US
Switch
“S4”
Switch “S4” position (see fig 17-11 and
17-12)
On or Off
On
On
On
Off
On
On
Off
N/A = Not Applicable