5
0
60T - 280T
COSMOGAS
15.5 - Converting appliance
models from 100T to 280T from
one type of gas to another
Appliances from 100T to 280T are multi-burners, which means
that the type of gas must be converted on every burner.
ATTENTION !!! Read these instructions carefully
before changing the gas:
- The gas equipment must be installed, calibrated or
modified by specialised personnel according to the
terms of the law;
- Check and be sure that the type of gas that is supplying
the appliance is compatible with the regulation kit you
have;
- Do not supply the appliance with a different type of gas
than those provided for.
Contents:
The Kit (standard supplied with the appliance) is made up of
- label bearing the new type of gas;
- a gas nozzle for every burner;
- an instruction sheet;
To change the gas, proceed as follows:
1 - Convert “Burner 1” (MASTER). See figure 15-5 to
identify “Burner 1” (MASTER);
2 - Convert “Burner 1” (MASTER), following points 1 to 16
in section 15.4;
After converting “Burner 1”, proceed with “Burner 2” as
described below:
3 - Convert “Burner 2”, following points 1 to 16 in section
15.4;
After converting “Burner 2”, proceed with “Burner 3” (if
present) as described below:
4 - Convert “Burner 3”, following points 1 to 16 in section
15.4;
After converting “Burner 3”, proceed with “Burner 4” (if
present) as described below:
5 - Convert “Burner 4”, following points 1 to 16 in section
15.4;
After converting all the Burners, proceed as described
below:
6 - Check the gas inlet pressure as described in section
15.7;
7 - Check the appliance output heat as described in section
15.9;
ATTENTION !!!
The measurements must be
taken with calibrated instruments that ensure an
accurate reading.
8.- on the front casing of the appliance, in the place of the
label identifying the old adjustment status, apply the
self-adhesive plate
(see figure 15-7), bearing the new
adjustment status of the appliance, as follows: apply
label “B” if the appliance was converted from methane to
LP gas; apply label “A” if the appliance as converted from
LP gas to methane.
ATTENTION !!!
If you smell gas:
A - Do not activate any electrical appliances,
including telephones or any objects that could
create sparks;
B - Immediately open the doors and windows to
create an air current to quickly rid the room of
gas;
C - From another room or from a neighbour’s
if there is no other room, immediately call a
professionally qualified technician or the gas
supply company. If they are unavailable, call the
Fire Brigade.
15 - COMMISSIONING
D - Gas inlet pressure plug.
E - CO2 adjustment screw.
F - Factory default adjustment screw (do not touch).
Figure 15-6 - Gas valve
E
D
F
E
D
F
020010.01.022