9.8 - Replace the machine
floor heater wire
1.- Disconnect the upper power supply and remove the fan
as per section 9.7;
2.- Remove the heater wire retaining bracket;
3.- Disconnect the power quick connector and remove the
wire;
4.- Connect the new wire and repeat the previous steps in
reverse.
Figure 9-16 Bottom wire heater
Wire heater
Quick connector
Figure 9-17 Disconnect the quick connector
Figure 9-18 Connect the new wire heater