39
FRYO PI
COSMOGAS
7 - USO
Parameter
Description
Unit of
measure
Range
Factory
value
C8
Auxiliary source priority for heating mode
(Do not change)
/
0 (low), 1 (high)
1
C9
Demand algorithm of the integrative resistance to the heating.
The higher the value, the more late the resistance starts.
/
0...600
45
Press the key to access the following parameters:
d1
For the “d” parameters refer to section 7.4 from “d1” to “dC”.
Press the key to access the following parameters:
E1
Heat recovery function (N/A) (Do not change)
/
0 (invalid), 1 (valid)
0
E2
DHW restart based on ΔT during heat recovery function (N /
A) (Do not change)
°C
5...10
5
E3
DHW stop based on ΔT during heat recovery function (N / A)
(Do not change)
°C
1...10
5
E4
Heating offset temperature during heating priority operation
(N/A) (Do not change)
°C
3...20
5
E5
Maximum number of minutes of heating operation during
heating priority operation (N/A) (Do not change)
min
20...180
30
E6
Minimum number of minutes of DHW operation during hea
-
ting priority operation (N/A) (Do not change)
min
20...180
50
E7
Intervention request of auxiliary heating source in DHW
during operation with heating priority (N/A) (Do not change)
/
0 (no), 1 (yes)
0