7 - USE
7.1 - Introduction to the display
Symbol
Function
Description
Heating
Heating symbol: appears when heating is on (Section 7.5, Parameter “08” = 1 o 2) and flashes when it is
in operation (HS-GND input closed, see section 5.7).
Cooling
Cooling symbol: appears when cooling is on (Section 7.5, Parameter “08”= 1 or 2) and flashes when it is
in operation (CS-GND input closed, see section 5.7).
Domestic hot water
Domestic hot water symbol (DHW): appears when DHW is on (section 7.5, Parameter “08”= 0, 2 or 4)
and flashes when it is in operation.
Auxiliary heater
The symbol appears on the display when the integrative electrical resistance is called.
Antifreeze function
Protection function to avoid freezing: the icon is on during protection.
Supply temperature
WARNING !!! This indicator must always be active. If it is not active, press and hold the “M”
button until “
” appears.
Supply setpoint
temperature
Shows the temperature set for the supply water in heating or cooling.
Silent mode
Reduces the compressor and fan speed in the set period.
The symbol appears when this mode is set as active.
Defrost
Icon appears when the defrost function is on.
Temperature
unit of measure
This icon shows if the temperature is in °C or °F.
Compressor indicator
Show the actual speed of compressor: the symbol appears when it is in operation.
Time or parameters
The icon represents the time, when you are in main screen, and parameters, when you enter in one of
available menù (Figure 7-10).
Timer (N/A)
WARNING !!
!
If this icon is present, follow section 7.2.5 to turn it off.
ON/OFF button
This button turns the appliance on or off.
Operation mode button
The button switches between the various operating modes: heating / cooling, DHW or combinations.
WARNING !!! For automatic operation (control via external inputs in Figure 5-10) always leave the
and icons
and
displayed at the same time (section 7.2.3).
Up button
Increase the value of the selected parameter. Scroll through the parameters and change their value
during settings.
Down button
Decrease the value of the selected parameter. Scroll through the parameters and change their value
during settings.
Set button
Multifunction button: functions are described from time to time in the various sections.
Clock button
Multifunction button: functions are described from time to time in the various sections.
Figure 7-1 - Display