22
CONFIGURING CHECKMATE™ DL WITH RDC CONFIGURATION
Once the span is entered, press the
Enter (F1)
key to proceed to the
Enter
Probe Alloy
display:
Enter Probe Alloy
> <
Enter Clr BkSp Exit
The
Enter Probe Alloy
display allows the user to enter up to eight (8) alpha
or numeric characters to identify the alloy of the probe element for reference
purposes only. It does not affect the calculation of corrosion rates. At this point,
the Checkmate DL will proceed to the
Is This A Corrotemp Probe?
display.
Make the appropriate selection,
Yes (F1)
or
No (F4)
. Checkmate will proceed
to the
RDC Time Interval
display; make the appropriate selection to advance
to the next screen. Checkmate DL will automatically proceed to conclude
the con
fi
guration process. Scroll up in this section (
Manually Con
fi
guring a
Corrosometer or Corrater Probe attached to a RDC/ER-210
) for step by step
illustrated descriptions.
If type
E
or
F
is selected, following
Select Probe Alloy
display will appear:
Select Probe Alloy
> , <
> <
Enter Up Down Exit
Scroll up or down through the list by repeatedly pressing the
Up (F2)
key or the
Down (F3)
key. When the desired probe element selection is displayed, press
the
Enter (F1)
key to accept the selection. Next screen
(Is This A Corrotemp
Probe?)
will prompt to choose
Yes (F1)
or
No (F4)
. Make the appropriate
selection. Checkmate DL will proceed to the
RDC Time Interval
display; make
the appropriate selection to advance to the next screen. Checkmate DL will
automatically proceed to conclude the con
fi
guration process. Scroll up in this
section (
Manually Con
fi
guring a Corrosometer or Corrater Probe attached to
a RDC/ER-210
) for step by step illustrated descriptions.
If
OTHER
is selected in the
Select Probe Alloy
display as shown
below, pressing the
Enter (F1)
key will advance the display to
the
Enter Probe Alloy
screen. The
Enter Probe Alloy
display
allows the user to enter up to eight (8) alpha/numeric characters
to identify the alloy of the probe element for reference purposes
only. It does not affect the calculation of corrosion rates. Press
Enter (F1)
again, follow the prompts and enter the necessary
values to conclude the con
fi
guration process. Scroll up in this
section (
Manually Con
fi
guring a Corrosometer or Corrater
Probe attached to a RDC/ER-210
) for step by step illustrated
descriptions.
Select Probe Alloy
> OTHER <
>OTHER<
Enter Up Down Exit
Содержание Checkmate DL
Страница 6: ...iv TABLE OF CONTENTS ...
Страница 8: ...ii FIGURES AND TABLES ...
Страница 10: ...2 INTRODUCTION Figure 1 2 Checkmate DL Instrument Specifications ...
Страница 18: ...10 BASICS OF CHECKMATE DL ...
Страница 22: ...14 INITIALIZING CHECKMATE DL TO WORK WITH CORRDATA SYSTEM ...
Страница 40: ...32 CONFIGURING A RDC ER 210 USING CHECKMATE DL ...
Страница 46: ...38 READING A RDC ER 210 WITH THE CHECKMATE DL ...
Страница 52: ...44 TRANSFERRING RDC ER 210 DATA TO THE PC ...
Страница 60: ...52 READING A DATA LOGGER WITH THE CHECKMATE DL ...
Страница 64: ...56 TRANSFERRING DATA LOGGER DATA TO THE PC ...
Страница 66: ...58 TROUBLESHOOTING GUIDE ...
Страница 67: ...CHECKMATE DL 59 ...
Страница 68: ...60 ...
Страница 69: ...CHECKMATE DL 61 ...
Страница 70: ...62 ...
Страница 71: ...CHECKMATE DL 63 Interconnect Diagram Drawing Appendix B Figure B 1 Interconnect Diagram Drawing ...