20
CONFIGURING CHECKMATE™ DL WITH RDC CONFIGURATION
The
Enter Probe Alloy
display allows the user to enter up to
eight (8) alpha/numeric characters to identify the alloy of the
probe element for reference purposes only. It does not affect the
calculation of corrosion rates.
Press the
Enter (F1)
key to advance to the next display shown below:
Is This A Corrotemp
Probe?
Yes No
Make the appropriate selection, Checkmate DL will proceed to the next display:
RDC Time Interval
( 1 - 24 ) > < Hours
Enter Clr Mins Exit
Key in the desired read time interval for RDC/ER-210 readings (default selection
is presented in hours) and press
Enter (F1)
. Pressing the
Enter (F1)
without
specifying a value will default the read interval to One (1) hour. Press the
Mins
(F3)
key to change the time interval selection to minutes (shown below):
RDC Time Interval
( 5 - 30 ) > < Mins
Enter Clr Hrs Exit
Key in the desired minute read interval and press the
Enter (F1)
key to advance
to the next display. Pressing the
Enter (F1)
without specifying a value will default
the read interval to
fi
ve (5) minutes. The minimum read time interval for a Four
(4) Channel RDC is 15 minutes. Although Corrosometer probes attached to RDC
– COT/ER-210 may be set up to have a 5 minute read time interval, 4 Channel
RDC will change the read time to 15 minutes (RDC–COT/ER-210 (one channel)
will retain the 5 minute read interval).
The minimum read time interval offered for Corrater and Corrater Flush probe
is 30 minutes. In this case, choosing
Mins (F3)
will show the following display.
Press
OK (F1)
to accept,
Hrs (F3)
to return to hourly
RDC/ER-210 Time Interval
display, or
Exit (F4)
to exit to
Con
fi
guration Options
screen:
RDC Time Interval
Set to 30 Mins
OK Hrs Exit
Содержание Checkmate DL
Страница 6: ...iv TABLE OF CONTENTS ...
Страница 8: ...ii FIGURES AND TABLES ...
Страница 10: ...2 INTRODUCTION Figure 1 2 Checkmate DL Instrument Specifications ...
Страница 18: ...10 BASICS OF CHECKMATE DL ...
Страница 22: ...14 INITIALIZING CHECKMATE DL TO WORK WITH CORRDATA SYSTEM ...
Страница 40: ...32 CONFIGURING A RDC ER 210 USING CHECKMATE DL ...
Страница 46: ...38 READING A RDC ER 210 WITH THE CHECKMATE DL ...
Страница 52: ...44 TRANSFERRING RDC ER 210 DATA TO THE PC ...
Страница 60: ...52 READING A DATA LOGGER WITH THE CHECKMATE DL ...
Страница 64: ...56 TRANSFERRING DATA LOGGER DATA TO THE PC ...
Страница 66: ...58 TROUBLESHOOTING GUIDE ...
Страница 67: ...CHECKMATE DL 59 ...
Страница 68: ...60 ...
Страница 69: ...CHECKMATE DL 61 ...
Страница 70: ...62 ...
Страница 71: ...CHECKMATE DL 63 Interconnect Diagram Drawing Appendix B Figure B 1 Interconnect Diagram Drawing ...