14. Equipment Disposal

According to Directive 2012/19/EU of the European Parliament and Council of 
4 July 2012 on waste electrical and electronic equipment (WEEE), the Corning® 
MicroDEN® unit is marked with the crossed-out wheeled bin and must not be 
disposed of with domestic waste. 

Consequently, the purchaser shall follow instructions for reuse and recycling of 
waste electronic and electrical equipment (WEEE) provided with the product and 
available at www.corning.com/weee

13. Limited Warranty 

Corning Incorporated (Corning) warrants that this product will be free from 
defects in material and workmanship for a period of one (1) year from date of 
purchase. CORNING DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESSED 
OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR 
OF FITNESS FOR A PARTICULAR PURPOSE. Corning’s sole obligation shall be to 
repair or replace, at its option, any product or part thereof that proves defective 
in material or workmanship within the warranty period, provided the purchaser 
notifies Corning of any such defect. Corning is not liable for any incidental or 
consequential damages, commercial loss or any other damages from the use of 
this product.
This warranty is valid only if the product is used for its intended purpose 
and within the guidelines specified in the supplied instruction manual. This 
warranty does not cover damage caused by accident, neglect, misuse, improper 
service, natural forces or other causes not arising from defects in original 
material or workmanship. This warranty does not cover motor brushes, fuses, 
light bulbs, batteries or damage to paint or finish. Claims for transit damage 
should be filed with the transportation carrier.
In the event this product fails within the specified period of time because of  
a defect in material or workmanship, contact Corning Customer Service at: 
USA/Canada 1.800.492.1110, outside the U.S. +1.978.442.2200, visit  
www.corning.com/lifesciences

, or contact your local support office.

Corning’s Customer Service team will help arrange local service where available 
or coordinate a return authorization number and shipping instructions. 
Products received without proper authorization will be returned. All items 
returned for service should be sent postage prepaid in the original packaging or 
other suitable carton, padded to avoid damage. Corning will not be responsible 
for damage incurred by improper packaging. Corning may elect for onsite 
service for larger equipment.
Some states do not allow limitation on the length of implied warranties or the 
exclusion or limitation of incidental or consequential damages. This warranty 
gives you specific legal rights. You may have other rights which vary from state 
to state.
No individual may accept for, or on behalf of Corning, any other obligation of 
liability, or extend the period of this warranty.
For your reference, make a note of the serial and model number, date of 
purchase, and supplier here.

Serial No. ___________________________   Date Purchased _________________________

Model No.  ___________________________________________________________________

Supplier _____________________________________________________________________

Содержание MicroDEN

Страница 1: ...hnical information visit www corning com lifesciences or call 800 492 1110 Outside the United States call 1 978 442 2200 or contact your local Corning sales office Corning Incorporated Life Sciences 8...

Страница 2: ...autoclave this unit Do not perform the sterilization cycle of an incubator with the MicroDEN unit inside Do not use acetone to clean the unit Always use the provided external power supply to power the...

Страница 3: ...nts 1 Corning MicroDEN unit Cat No 431276 requires standard electrical outlet 2 Corning consumable set Cat No 431277 3 Corning storage bottle Cat No 431278 4 Enriched monocytes MOs 5 Differentiation m...

Страница 4: ...t a wall to prevent disturbing the cultured cells The cell culture flasks may be seeded with either enriched MOs or with peripheral blood mononuclear cells PBMCs where the MOs are enriched through pla...

Страница 5: ...ow through the unclamped tube Method 2 Pump Perfusion 1 Unclamp the pumps by pressing upwards at the dotted triangle on the pump head 2 Place the tubing onto the pump rollers The colored tubing marker...

Страница 6: ...emptied on Day 3 1 Turn the Corning MicroDEN unit OFF disconnect the power cord and remove from the incubator 2 Lightly spray the MicroDEN system with 70 ethanol and place inside the biosafety cabine...

Страница 7: ...e new storage bottle containing differentiation medium Disconnect the empty bottle MPCs and connect the new storage bottle MPCs to the inlet side tubing 8 Transfer the Corning MicroDEN system from the...

Страница 8: ...he flasks back onto the thermoform tray with the corner notch of each flask in the upper right position 10 Repeat Steps 1 9 for a second cold buffer wash NOTE Flasks can be harvested individually by u...

Страница 9: ...anol to disinfect before placing in the biosafety cabinet After use the unit can be cleaned with 70 ethanol or 10 bleach solution The unit should be stored upright in a cool dry environment when not i...

Страница 10: ...riginal material or workmanship This warranty does not cover motor brushes fuses light bulbs batteries or damage to paint or finish Claims for transit damage should be filed with the transportation ca...

Отзывы: