Instruction Manual

Corning® MicroDEN® Platform

Table of Contents

Safety Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2.  Getting Started  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

3.  Material Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

4.  Setting up the Corning MicroDEN Unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

5.  Cell Seeding  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

6.  Differentiation Medium Loading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

7.  Priming   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

8.  Expansion  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

9.  Harvest (Day 6)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

10.  Cleaning and Care   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

11.  Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

12.  Technical Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

13.  Limited Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

14.  Equipment Disposal   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Safety Information

To avoid personal injury while using the Corning® MicroDEN® unit:

Take care while installing tubing; pinch points exist between the upper and 
lower section of the pump door.

Do not operate the pumps while pump doors are open

To avoid damage or malfunction of the MicroDEN unit:

Ensure the unit is always placed on a firm, stable, and horizontal surface.

Do not attempt to remove or repair the outer case of the unit.

Never attempt to repair, disassemble, or modify this unit yourself, as tampering 
with this product may result in injury or fire.

Do not drop the unit or allow objects to fall onto it.

Do not allow the unit to be submerged or immersed in liquid.

Do not place any objects on top of this unit, and never stand or lean on the 
unit. Failure to do so may cause the equipment to fall or collapse, which may 
result in breakage and/or injury.

Do not autoclave this unit.

Do not perform the sterilization cycle of an incubator with the MicroDEN unit 
inside.

Do not use acetone to clean the unit.

Always use the provided external power supply to power the MicroDEN unit.

Emissions and Interference – Warning Statements

FCC Part 15: This equipment has been tested and found to comply with the limits 
for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and 
used in accordance with the instruction manual, may cause harmful interference 
to radio communications. Operation of this equipment in a residential area is 
likely to cause harmful interference in which case the user will be required to 
correct the interference at his own expense.

ICES-003: CAN ICES-3(A)/NMB-3(A)

These warning statements apply to Class A products for business use:

This device complies with part 15 of the FCC Rules and with Industry Canada 
license-exempt RSS standard(s).

Operation is subject to the following two conditions: (1) This device may not 
cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.

Cet appareil est conforme à la partie 15 de la réglementation de la FCC et à 
Industrie Canada exempts de licence standard RSS (s).

Содержание MicroDEN

Страница 1: ...hnical information visit www corning com lifesciences or call 800 492 1110 Outside the United States call 1 978 442 2200 or contact your local Corning sales office Corning Incorporated Life Sciences 8...

Страница 2: ...autoclave this unit Do not perform the sterilization cycle of an incubator with the MicroDEN unit inside Do not use acetone to clean the unit Always use the provided external power supply to power the...

Страница 3: ...nts 1 Corning MicroDEN unit Cat No 431276 requires standard electrical outlet 2 Corning consumable set Cat No 431277 3 Corning storage bottle Cat No 431278 4 Enriched monocytes MOs 5 Differentiation m...

Страница 4: ...t a wall to prevent disturbing the cultured cells The cell culture flasks may be seeded with either enriched MOs or with peripheral blood mononuclear cells PBMCs where the MOs are enriched through pla...

Страница 5: ...ow through the unclamped tube Method 2 Pump Perfusion 1 Unclamp the pumps by pressing upwards at the dotted triangle on the pump head 2 Place the tubing onto the pump rollers The colored tubing marker...

Страница 6: ...emptied on Day 3 1 Turn the Corning MicroDEN unit OFF disconnect the power cord and remove from the incubator 2 Lightly spray the MicroDEN system with 70 ethanol and place inside the biosafety cabine...

Страница 7: ...e new storage bottle containing differentiation medium Disconnect the empty bottle MPCs and connect the new storage bottle MPCs to the inlet side tubing 8 Transfer the Corning MicroDEN system from the...

Страница 8: ...he flasks back onto the thermoform tray with the corner notch of each flask in the upper right position 10 Repeat Steps 1 9 for a second cold buffer wash NOTE Flasks can be harvested individually by u...

Страница 9: ...anol to disinfect before placing in the biosafety cabinet After use the unit can be cleaned with 70 ethanol or 10 bleach solution The unit should be stored upright in a cool dry environment when not i...

Страница 10: ...riginal material or workmanship This warranty does not cover motor brushes fuses light bulbs batteries or damage to paint or finish Claims for transit damage should be filed with the transportation ca...

Отзывы: