Calibrating a Motor
Calibration of motors is typically required when a motor or any associated barrel components (i.e., scrapper blades,
seal, faceplate, etc.) is removed or replaced. Calibration establishes a new baseline for the motor assembly. This
allows the system to determine proper viscosity settings for the new motor. When a new motor is installed in the unit
or any of the barrel components are changed or adjusted, the motor should be calibrated by performing the
procedure described in Table 29.
CAUTION
:
!
Calibration must be performed when the product in the barrel is completely liquid. There must not be any ice on the
scraper blade.
Table 27.
Button
Description
BACK
Returns the display to the Select menu
CAL
Verifies the motor settings of a new motor.
-
Decrements the highlighted field
+
Increments the highlighted field
Table 28.
Step
Action
Procedure
1
Set barrel for Motor Type
From the Maintenance menu (Figure 24.), open the Motor Setup
menu, shown in Figure 33.
2
Select the barrel
Use the Up and Down arrows to highlight the desired barrel
3
Select the proper motor type
Press the + or - buttons at the bottom of the display to select the
proper motor type
4
Complete the procedure
Press the BACK button at the bottom of the display to save the
settings and return to the Setup menu.
Table 29.
Step
Action
Procedure
1
Re-assemble barrel
It is VERY IMPROTANT that calibration be performed when the product in the barrel
is in a 100% liquid state. There can be no ice in the barrel or on the beater bar.
2
Defrost the barrel
Select DFRST on the Barrel Status menu (Figure 13.). It is very important that cali-
bration be performed on a fully defrosted barrel (outlet temperature must be 41
°
F or
barrel must be purged and refilled with new product).
3
Select Motor Setup
Use the Up and Down arrows to highlight MOTOR SETUP on the Maintenance
menu.
4
Select the barrel
Use the Up and Down arrows to highlight the desired barrel
5
Start calibration
Press the CAL button at the bottom of the Motor Setup menu to start the calibration
process.
The calibration cycle continues for five (5) minutes to allow the gearbox to stabilize at
temperature and ensure correct calibration. At that time the motor stops and it is cali-
brated.
6
Complete the proce-
dure
Press the BACK button at the bottom of the display to return to the Maintenance
menu.