Viper Service Manual
© 2008-2016, Cornelius Inc.
- 21 -
Publication Number: 621260373SER
Unit Data Menu
The Unit Data screen, shown in Figure 15., provides information about the individual barrels in the system. When
DATA is highlighted and the GO button is pressed on the Select menu, the display shows the first barrel in the
system and some of its parameters. To view the next barrel, press the down arrow on the right side of the display.
Continue pressing the down arrow to view the data on all barrels in the system. Refer to Table 4 for button functions.
UNIT
DATA
12:51P
MAR 04
#1 FREEZE
OUTLET TEMP 33
o
F
VISCOSITY: 9
REFRIGERATION: ON
DEFROST TIMER: 2:50:23
BACK
BRL
UNIT VER
AV OZ/HR/3 HR: 80
Figure 15. Unit Data Screen
Error Status Menu
The Error Status menu, shown in Figure 16., displays any current errors contained in the Error Messages List.
There are three types of errors that can be generated by the system. These error types and a description of their
meaning are listed in Table 5.
MAINT
Displays and opens Maintenance menu, if security is off or
accessed
GO
Opens the highlighted selection on the current menu
Table 4.
Button
Description
BACK
Returns the display to the Select menu
BRL
Displays the data for a single barrel, including Outlet Temperature,
Viscosity, if Refrigeration is On or Off, Average Ounces of product
dispensed per hour for the last three hours and Defrost Lock Time
until next defrost
UNIT
Displays the real time input voltage and frequency being supplied to
the unit and the low, high or both refrigeration pressures for the unit,
depending on the settings of the compressor sensors in the Unit
Data screen, as shown in Figure 36..
VER
Displays the version number of the UI, I/O, Motor and Status boards
installed in the unit
Table 5.
Error Type
Description
System
A System error displays the same information across all barrels in the
unit.
Barrel
A Barrel error is limited to a specific barrel
Table 3.
Button
Description