Viper Service Manual
© 2008-2015, Cornelius Inc.
- 49 -
Publication Number: 621260373SER
Flushing the System
Flush the wash water from the system by performing the procedure in Table 41.
CAUTION
:
!
Flush the system thoroughly, residual sanitizing solution left in the system may create a health hazard.
9.
Use the brush provided with the unit to clean the relief port and clean the outlet of the dispense valve with san-
itizing solution.
10. From
the
Barrel Status menu, press the SPIN
button while highlighting the appropriate barrel. This starts the
scraper blade. Allow blade to operate for minimum of 10, but no more than 15 minutes. Turn the scrapper
blade off by pressing the
OFF button.
11.
Place a large container under the dispense valve and drain as much sanitizing solution as possible from the
barrel.
12.
When the pressure in the barrel drops, from the
Barrel Maintenance menu, press the
PURGE button to re-
pressurize the barrel with CO
2
. As sanitizing solution level lowers in the barrel, partially close the valve to avoid
spurting.
Table 41.
Step
Action
1.
Turn the Product/BRIX valve to the Product position.
2.
Manually open the manual water flow valve to start filling the barrel with wash water. At the same time, open
the faceplate relief valve until water comes out.
3.
From the Barrel Status menu, press the SPIN button while highlighting the appropriate barrel. This starts the
scraper blade. Allow the blade to operate for fifteen seconds, then turn barrel OFF by pressing the OFF but-
ton.
4.
To drain the water from the system, turn the barrel OFF.
5.
Place a container under the barrel dispensing valve. Open the dispensing valve and dispense all rinse water
from the barrel. When the pressure in the barrel drops, from the Barrel Maintenance menu, press the PURGE
button to re-pressurize the barrel with CO
2
. As the wash water level lowers in the barrel, partially close the
valve to avoid spurting.
6.
Remove the sanitizing fitting (p/n cc 28688) from the BIB connector and connect a BIB containing syrup to
the syrup line.
7.
Rotate the Product/BRIX valve to the BRIX position and open the valve at the end of the tube.
8.
Hold a waste container under the BRIX tube to collect the sanitizing solution from the syrup line and open the
manual syrup flow valve to start filling the syrup line with syrup. Continue to hold open the syrup flow valve
until syrup starts coming out of the BRIX tube.
9.
Perform a BRIX setup. See “BRIX Setup Menu” on page 34.
10.
Fill the barrel with product as described in Table 20.
11.
Perform motor calibration. See “Calibrating a Motor” on page 38.
Table 40.
Step
Action